Butane Gas Sensor, Transmitter, Detector Analyzer

ALVI Automation Gas Alarm System India offer Butane sensor transmitter / detector/ analyser from MSR Electronic, Germany with following features:

  • Measuring range: 0-100% LEL (lower explosive limit), 0-100% Vol (analysis)
  • Technology: Pellistor / catalytic bead (flammability monitoring), Infra-red
  • Output: 4-20mA, 0-10V, RS485 modbus, Lon, BacNET
  • Enclosure: IP44, IP54, IP65
  • Certificate: UL 61010, UL 2075, ATEX EExd, ATEX EExn, CE
  • Mounting: wall mountable, duct mountable
  • Installation area: safe area, hazardous area, explosion-proof

Continue reading “Butane Gas Sensor, Transmitter, Detector Analyzer”

Battery charging room, UPS / inverter room Hydrogen Sensor

Battery rooms or battery charging bays or battery charging stacks are being widely used in Data Center, UPS Systems, Renewable Energy Sources like Solar Plants, Wind farms, Submarines, Naval Vessels and Underground Bunkers etc.
These batteries when being charged generate, liberate highly explosive Hydrogen (H2) gas. The LEL(Lower Explosive Limit) of Hydrogen (H2) is 4 % Vol. and the UEL (Upper Explosive Limit) is 77 % Vol. Hydrogen (H2) is lighter than air and travels towards ceiling in an enclosed battery room.
The potential risk of this Hydrogen (H2) generation liberation in battery rooms are:

Continue reading “Battery charging room, UPS / inverter room Hydrogen Sensor”

Methane (Natural Gas), CNG Sensor, Poisoning protected Transmitter

ALVI Automation Gas Alarm System India offer Methane / CNG / PNG sensor transmitter / detector/ analyser from MSR Electronic, Germany with following features:

  • measuring range: 0-100% LEL (lower explosive limit), 0-100% Vol (analysis)
  • technology: Pellistor / catalytic bead (flammability monitoring), Infra-red
  • output: 4-20mA, 0-10V, RS485 modbus, Lon, BacNET
  • Enclosure: IP44, IP54, IP65
  • Certificate: UL 61010, UL 2075, ATEX EExd, ATEX EExn, CE
  • Mounting: wall mountable, duct mountable
  • Installation area: safe area, hazardous area, explosion-proof

Continue reading “Methane (Natural Gas), CNG Sensor, Poisoning protected Transmitter”

Ripening Fruit on an Industrial Scale with MSR Ethylene

ALVI Automation (India) Alarm system Pvt Ltd. Offer you 

Ripening of fruit is a problem, particularly when you want to sell that fruit. If the fruit ripens too early it will be overripe when it gets to the customer. If it is very under-ripe when it gets to the shelf the customer might not want to buy it.
It also causes a problem for transport. Ripening fruit bruises more easily and one spoiled fruit as they say can spoil the whole lot. When you are transporting a truck full of fruit this is a real problem. Fruit travel much better when they are under-ripe. Firmer, they bruise less easily. They are also less susceptible to spoiling. However fruit doesn’t taste good before it is ripe.

To sell well, fruit needs to get to customers at the perfect point between becoming ripe and being over ripe. The ability to control the ripening process is therefore very useful. It allows fruit producers and distributors to pick and transport fruit when it is under-ripe and ripen it just before putting it on the shelves.
Continue reading “Ripening Fruit on an Industrial Scale with MSR Ethylene”

Ethyl Acetate Sensor

Ethyl Acetate Sensor, analyzer, transmitter for industrial, oil, chemical application, Ethyl Acetate sensor, transmitter, analyzer for flammability monitoring. ALVI Automation Gas Alarm India offer Ethyl Acetate sensor transmitter / detector/ analyser from MSR Electronic, Germany with following features:

  • measuring range: 0-100% LEL (lower limit), 0-100% Vol (analysis)
  • technology: Pellistor / catalytic bead (flammability monitoring), Infra-red
  • output: 4-20mA, 0-10V, RS485 modbus, Lon, BacNET
  • Enclosure: IP44, IP54, IP65
  • Certificate: UL 61010, UL 2075, ATEX EExd, ATEX EExn, CE
  • Mounting: wall mountable, duct mountable
  • Installation area: safe area, hazardous area, explosion-proof

Continue reading “Ethyl Acetate Sensor”

MSR Gas Controller/PLC

Model: DGC 05

Features:

  • For monitoring analog (4-20mA, 0-10V signals) & digital (DGC, Modbus) transmitters
  • With LCD Display, 230 VAC Power Supply, auto-diagnostic watchdog, errorlog, datalogging optional
  • Wall-mounted, IP65 enclosure
  • 4;8;12;16;202;24;32….. upto 98 channel control systems to accept gas sensor/transmitter inputs
  • Transmitter types (CO, NH3, NO2, Freon, CO2, O2, SO2, H2S explosive/flammable, temp., humidity & others)
  • Built-in fan logic controls (for car park fans)
  • RS485, Modbus, LON/BAC-net interfaces
  • Modular and expandable via EP modules for upto 98 channel (DGC-digital systems)

MSR Stand-alone Gas Sensor Controller

Model: SPC
with integrated gas sensor cell (inbuilt)

Features:

  • Available for all toxic, flammable / combustible and oxygen sensor Gases: CO, NH3, NO2, CO2, (for DCV), H2S, CL2, SO2, HCN & others
  • Integral Gas Sensors
  • Integral display, LCD, Keypad, alarm LEDs buzzer
  • 4-20mA output for PLC/BMS, relay for A-V alarm
  • Stand alone operation for fan logic control or alarms