Hazardous Gas Detection and Real Time Monitoring Sensor

MSR Germany has a variety of hazardous gas detectors to help you maintain a safe work environment. Choosing the proper gas monitoring equipment for the workplace is important in preventing worker exposure.

Our fixed monitoring systems and MSR controllers with remote gas monitoring sensor/transmitters utilize an array of sensor technologies allowing us to custom design a system that will provide the best solution for our customer’s gas detection requirements.

These various gas detection systems provide continuous real-time monitoring of a variety of hazardous toxic and combustible gases as well as oxygen with certifications like ATEX, SIL2 and IEC-Ex all under one roof.

Applications include industrial, commercial and manufacturing processes, oil and gas, petrochemicals, specialty chemicals, industrial refrigeration, water and wastewater treatment, plastics and fibers, pulp and printing, agriculture, medical and pharmaceutical and much more.

For more details please contact us

MSR Germany ADL 51 1183 Hydrogen Cyanide Gas Data Logger

Gas Alarm Systems – India (http://www.alviautomation.com)  in association with Gas Alarm Systems – Australia (http://www.gasalarm.co.au) offer MSR Germany ADL 51 1183 Hydrogen Cyanide Gas Data Logger

Product Description

ADL 51 1183 Hydrogen Cyanide (HCN) Gas Data Logger is a portable gas measuring device with integrated datalogger for the continuous monitoring of the ambient air to detect the presence of toxic gases and vapors, as well as of oxygen. Up to 16,000 measuring values are recorded in the datalogger. For the detection and recording of toxic gases and vapors, as well as of oxygen in a wide range of commercial applications.

Features

  • Suitable for toxic gases and vapors, as well as for oxygen
  • Measuring cycle adjustable from 2 sec. to 5 hours
  • Datalogger for 16,000 measuring values
  • Data readout via the USB port
  • Internal rechargeable battery: Lifetime according to sensor type
  • Certified calibration

MSR Germany PolyXeta®2 Sensor for combustible gases in zone 1, sealed

Gas Alarm Systems India(http://www.alviautomation.com) in association with Gas Alarm Systems Australia (http://www.gasalarm.co.au) offer MSR Germany PolyXeta®2 Sensor for combustible gases in zone 1, sealed.

Microprocessor based gas sensor with 4 – 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors within the lower explosive limit (LEL) by means of a catalytic sensor element (pellistor) or an infrared sensor element. The calibration of sensors without LCD display is carried out via the calibration device Cal PX or the PC software PC-Soft 80. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red. The gas sensor is sealed and thus the housing in zone 1 can be opened during operation at any time (Ex demb[ib]).
APPLICATION
The PolyXeta®2 sensor is used in industrial areas like oil/gas industry, biogas plants, petrochemical industry, power plants etc. in Ex-Zone 1. The PolyXeta®2 sensor is also suitable for commercial areas like gas transfer stations etc. With the 4 – 20 mA / RS485-ModBus output signal the sensor is suitable for connection to the PolyGard®2 gas controller series by MSR-Electronic, as well as to any other controller or automation devices. Optionally, the PolyXeta®2 sensor is also available with LCD display and relay output.

Continue reading “MSR Germany PolyXeta®2 Sensor for combustible gases in zone 1, sealed”

μ-gard® Analog CO Transmitter (2-In-1) for Carbon Monoxide with enhanced CO radical detection capability for very early smoldering fire and smoke detection (product of gas radicals generated due to products of combustion fire)

Gas Alarm Systems India(http://www.alviautomation.com) in association with Gas Alarm Systems Australia (http://www.gasalarm.co.au) offer MSR Germany μ-gard® Analog CO Transmitter (2-In-1) for Carbon Monoxide with enhanced CO radical detection capability for very early smoldering fire and smoke detection (product of gas radicals generated due to products of combustion fire)

DESCRIPTION
Analog transmitter for monitoring of carbon monoxide gases
and vapors in the ambient air. The product model is equipped with
enhanced capability of monitoring carbon monoxide radicals for
generating earliest signs for smoke and fire. It is ideal for
installation for parking area, garages, chiller rooms and heating,
as well as dusty & humid area like pharmaceuticals, coal mine,
conveyor belt, cement plant, thermal power plants, flour mills,
powder industries. The μ-Gard analog transmitter series MA is a
reliable gas detector.

Continue reading “μ-gard® Analog CO Transmitter (2-In-1) for Carbon Monoxide with enhanced CO radical detection capability for very early smoldering fire and smoke detection (product of gas radicals generated due to products of combustion fire)”

MSR Germany Defence CAMP/TENT Protection System: For Rapid Deployment Force

Gas Alarm Systems India(http://www.alviautomation.com) in association with Gas Alarm Systems Australia (http://www.gasalarm.co.au) offer MSR Germany Defence CAMP/TENT Protection System: For Rapid Deployment Force

APPLICATIONS:
Chemical, biological, Explosive Gases Terrorism Gas Threats Very Early Fire Detection
Toxic Gas Fumes from bombs, missiles Air Quality in bunkers, shelters Energy Saving / Carbon Credit
Suitable for:
· Rapid Equipping Force in Forward Operating Bases
· Team Putting TENT System / ventilation system
Base camps and other forward deployed operating bases are highly vulnerable to both conventional and
asymmetric/terrorist attacks. The frequency of attacks against Allied Forces during Operations Enduring Freedom
and Iraqi Freedom indicate that current and future force deployments face an increased probability of such attacks.
The high casualty rates and disruption to operations emphasize the need for enhanced protection of deployed
Allied Forces and other peace keeping operations. Conventional security measures provide little or no protection
from improvised lethal attacks. Previous attacks have exposed various weak points and shortcomings in current
systems of Camp Protection.
Sensor Platform X (SPX) is a module based software platform for sensor integration, data analysis, alert detection
and alert response handling. It provides an automated surveillance system that monitors different kinds of sensors,
performs sensor analysis and notifies and aids users in response to critical situations. SPX is a unified
management platform providing the customer with a customizable and easy scalable solution to collect physical
security sub-systems into one easy-to-manage system. Its ability to integrate and manage third-party systems suits
the needs of Military Camp Operations by consolidating information from various sources and presenting it in a way
that is clear and draws an operator’s attention to the most critical information. Our main focus areas are listed
below, but through our partners we can expand the delivery to fit the customer’s requirements
Our strategic partners (Australia, Germany, Norway) deliver products, systems and services such as:

Continue reading “MSR Germany Defence CAMP/TENT Protection System: For Rapid Deployment Force”

MSR Germany Polygard Sensor for combustible gases in Hazardous zone 1&2

Gas Alarm Systems(www.gasalarmSystem.com.au) Australia in association with Gas alarm systems India (www.gasalarmsystems.in) are  pleased to introduce MSR Germany, Polygard  sensor for oil/gas or other hazardous industry. .

The PolyXeta®2 sensor is used in industrial areas like oil/gas industry, biogas plants, petrochemical industry, power plants etc. in Ex-Zone 2. The PolyXeta®2 sensor is also suitable for commercial areas like gas transfer stations etc. With the 4 – 20 mA / RS485-ModBus output signal the sensor is suitable for connection to the PolyGard®2 gas controller series by MSR-Electronic, as well as to any other controller or automation devices. Optionally, the PolyXeta®2 sensor is also available with LCD display and relay output

Continue reading “MSR Germany Polygard Sensor for combustible gases in Hazardous zone 1&2”

MSR Polygard Ethylene Sensor for Toxic and Hazardous Oil/gas Industries

Gas Alarm Systems(www.gasalarmSystem.com.au) Australia in association with Gas alarm systems India (www.gasalarmsystems.in) are  pleased to introduce MSR Germany, Polygard Ethylene sensor for oil/gas industry. .
APPLICATION
The PolyXeta®2 sensor is used in industrial areas like oil/gas industry, biogas plants, petrochemical
industry, power plants etc. in Ex-Zone 1. The PolyXeta®2 sensor is also suitable for commercial areas
like gas transfer stations etc. With the 4 – 20 mA / RS485-ModBus output signal the sensor is
suitable for connection to the PolyGard®2 gas controller series by MSR-Electronic, as well as to any
other controllers or automation devices. Optionally, the PolyXeta®2 sensor is also available with LCD
display and relay output.

Continue reading “MSR Polygard Ethylene Sensor for Toxic and Hazardous Oil/gas Industries”

MSR Germany Gas Alarm PolyGard® Ethylene ,C2H4 Transmitter ADT53 1189 for Ripening of fruits

ALVI Automation India (www.alviautomation.com) in association with Gas alarm systems, Australia (www.gasalarm.com.au) are pleased to offer MSR Germany, Polygard Ethylene Gas monitor, transmitter for Ripening of fruits during transportation or storage.

DESCRIPTION

C2H4 transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect ethylene concentrations. Integrated in the transmitter there is a comfortable calibration routine with selective access release. The ADT-53 possesses a standard analog output (0) 4- 20 mA or (0) 2– 10 V DC, and an RS-485 interface. 2 relays with adjustable switching thresholds are available as an option.

Continue reading “MSR Germany Gas Alarm PolyGard® Ethylene ,C2H4 Transmitter ADT53 1189 for Ripening of fruits”

GAS ANALYZER, DETECTOR, MONITOR, CONTROLLER LIST.

Gas Type Measuring Range  Available Design Data sheet Type Available
Acetic Acid 0-100% LEL IP65 enclosure 125px Combustible, Flammable Gas Standalone Controller MA, ADT, MC2, SPC
Acetone 0-100% LEL hcl-sensor-transmitter-analyzer MA, ADT, MC2, SPC
Acetylene 0-100% LEL hcl-sensor-transmitter-analyzer MA, ADT, MC2, SPC
Air Quality CO2 + VOC ETHYLENE-sensor-toxic-transmitter-detector-analyzer MA, ADT, MC2, SPC
Ammonia (NH3) 0-300 / 1000 / 35,000 ppm, 0-100% LEL MSR12_005 MA, ADT, MC2, SPC
Benzene 0-100% LEL IP65 enclosure 125px MA, ADT, MC2, SPC
carbon dichloride oxide – Phosgene 0-1 ppm IP65 enclosure 125px MA, ADT, MC2, SPC
Carbon Dioxide 0-2000 / 5000 / 20,000 / 50, 000 ppm, 0-20% / 100% Vol blog pic MA, ADT, MC2, SPC
Carbon Monoxide 0-300 / 2000 ppm, 0-2% / 5% / 20% / 100% Vol MSR12_005 MA, ADT, MC2, SPC
Chlorine 0-5 / 10 / 20 ppm IP65 enclosure 125pxPolyGard MGC-03 with buzzer, without further options, housing C MA, ADT, MC2, SPC
Chlorine Dioxide  0-1 ppm PolyGard MGC-03 with buzzer, without further options, housing C MA, ADT, MC2, SPC
Cyclopentane 0-100% LEL IP65 enclosure 125px MA, ADT, MC2, SPC
Dinitrogen oxide (Laughing gas) 0-2000 ppm IP65 enclosure 125px MA, ADT, MC2, SPC
Ethane 0-100% LEL ethane-sensor-transmitter-analyzer MA, ADT, MC2, SPC
Ethyl Acetate 0-100% LEL ethane-sensor-transmitter-analyzerETHYLENE-sensor-toxic-transmitter-detector-analyzer MA, ADT, MC2, SPC
Ethyl Alcohol 0-100% LEL ETHYLENE-sensor-toxic-transmitter-detector-analyzer MA, ADT, MC2, SPC
Ethyl Mercaptan -200 ppm, 0-100% LEL ETHYLENE-sensor-toxic-transmitter-detector-analyzerIP65 enclosure 125px MA, ADT, MC2, SPC
Ethylene 0- 10 / 500 / 1000 / 2000 ppm, 0-100% LEL IP65 enclosure 125px MA, ADT, MC2, SPC
Ethylene Oxide 0-20 ppm images MA, ADT, MC2, SPC
Fluorine 0- 1 / 5 ppm FT_sensor_th MA, ADT, MC2, SPC
Formaldehyde 0-10 ppm IP65 enclosure 125px MA, ADT, MC2, SPC
Freon / Refrigerants 0-2000 ppm MA, ADT, MC2, SPC
Hydrazine 0-1 ppm IP65 enclosure 125px MA, ADT, MC2, SPC
Hydrogen 0-100% LEL download MA, ADT, MC2, SPC
Hydrogen Chloride 0 – 20 / 200 ppm downloaddownload MA, ADT, MC2, SPC
Hydrogen Cyanide 0-100 ppm MSR12_005 MA, ADT, MC2, SPC
Hydrogen Fluoride 0-10 ppm MA, ADT, MC2, SPC
Hydrogen Sulphide 0 – 50 / 200 ppm download MA, ADT, MC2, SPC
Iso butane 0-100% LEL download MA, ADT, MC2, SPC
Iso Butyl Alcohol 0-100% LEL MSR12_005download MA, ADT, MC2, SPC
Iso Pentane 0-100% LEL air-quality-iaq-sensor-transmitter-detector MA, ADT, MC2, SPC
Iso Propanol Alcohol 0-100% LEL 2-500x500 MA, ADT, MC2, SPC
Iso propyl alcohol 0-100% LEL 2-500x500 MA, ADT, MC2, SPC
LPG Liquefied Petrol Gas 0-100% LEL 2-500x500 MA, ADT, MC2, SPC
Mercaptan (thiols) (-SH) 0-10 ppm download MA, ADT, MC2, SPC
Methane 0-100% LEL

 

MSR12_005 MA, ADT, MC2, SPC
Methanol 0-100% LEL

 

download MA, ADT, MC2, SPC
Methyl ethyl ketone 0-100% LEL download MA, ADT, MC2, SPC
Natural Gas (CNG / PNG) 0-100% LEL MSR12_005 MA, ADT, MC2, SPC
n-Butane

 

0-100% LEL MA, ADT, MC2, SPC
n-Heptane 0-100% LEL MSR12_005download MA, ADT, MC2, SPC
n-Hexane 0-100% LEL MSR12_005 MA, ADT, MC2, SPC
Nitrogen Dioxide 0-10 / 20 ppm IP65 enclosure 125px MA, ADT, MC2, SPC
Nitrogen Oxide 0-25 ppm IP65 enclosure 125px MA, ADT, MC2, SPC
Nitrogen Trifluoride 5-50 ppm IP65 enclosure 125px MA, ADT, MC2, SPC
n-Octane 0-100% LEL MA, ADT, MC2, SPC
Nonane 0-100% LEL IP65 enclosure 125px MA, ADT, MC2, SPC
n-Pentane 0-100% LEL IP65 enclosure 125px MA, ADT, MC2, SPC
Oxygen 0-25% / 30% / 100% Vol IP65 enclosure 125px MA, ADT, MC2, SPC
Ozone 0-5 / 10/ 200 ppm MA, ADT, MC2, SPC
Petrol vapours 0-100% LEL IP65 enclosure 125px MA, ADT, MC2, SPC
Phosphine 0-5 ppm IP65 enclosure 125px MA, ADT, MC2, SPC
Propane 0-100% LEL IP65 enclosure 125px MA, ADT, MC2, SPC
Propyl alcohol 0-100% LEL MA, ADT, MC2, SPC
Propylene -propene 0-100%  LEL

 

MA, ADT, MC2, SPC
Silane 0-50 ppm MA, ADT, MC2, SPC
Styrene 0-100% LEL MA, ADT, MC2, SPC
Sulphur Hexafluoride 0-1000 ppm detector-analyzer MA, ADT, MC2, SPC
Sulphur Dioxide 0 – 10 / 20 ppm detector-analyzer MA, ADT, MC2, SPC
Tetrahydrothiophene

 

0-14 PPM MA, ADT, MC2, SPC
Toluene 0-100% LEL IP65 enclosure 125px MA, ADT, MC2, SPC
Trimethyl Amine 0-100PPM IP65 enclosure 125px MA, ADT, MC2, SPC
Trimethyl benzene 0-100% MA, ADT, MC2, SPC
Volatile organic compound (VOC) 0-4000% LEL IP65 enclosure 125px  

www.alviautomation.com

MA, ADT, MC2, SPC
Xylene 0-100% LEL http://www.alviautomation.com MA, ADT, MC2, SPC

 

ALVI Automation (Gas Alarm Systems) MSR Germany CH4, Methane Sensor, Polygard Gas Detector

ALVI Automation India (www.alviautomation.com) in association with Gas alarm systems, Australia (www.gasalarm.com.au) are  pleased to offer MSR Germany, Polygard Gas monitor for CNG, LNG, Natural Gas CH4, Methane.

Methane, CH4, is highly combustible gas and is also highly explosive at high concentrations.

Gas Alarm India with ALVI Technologies Australia (www.alvi.com.au) have MSR Gas Detector, Gas Analyzer, Gas Sensor, Gas Transmitter under MSR Polygard range to meet world critical safety standards for life and plant protection

Our product range includes MSR microgard, MA, MC2,  ADT, SPC.

All products and systems are manufactured by Germany , hence quality and reliability are assured. Continue reading “ALVI Automation (Gas Alarm Systems) MSR Germany CH4, Methane Sensor, Polygard Gas Detector”

ALVI Automation (Gas Alarm Systems) MSR infrared Sensor for CO2 Gas Detector

Gas Alarm Systems(www.gasalarm.com.au) Australia in association with Gas alarm systems India (www.gasalarmsystems.in) are  pleased to introduce MSR Germany, Infrared Gas Detector for CO2, carbon dioxide.

Carbon dioxide, CO2 is highly toxic gas and create health issue.

ALVI Automation India (www.alviautomation.com) with Gas Alarm Systems  Australia (www.alvi.com.au) have MSR Gas Detector, Gas Analyzer, Gas Sensor, Gas Transmitter under MSR Microgard & Polygard range to meet world critical safety standards for life and plant protection.

Our product range includes MSR microgard & polygard, MA, MC2, ADT, SPC, Polyzeta 2 for hazardous zone 1, zone 2 areas. it has IEC EX, ATEX certification with SIL 2.

All products and systems are manufactured in Germany , hence quality and reliability are assured. Continue reading “ALVI Automation (Gas Alarm Systems) MSR infrared Sensor for CO2 Gas Detector”

CO Carbon Monoxide Pollution, Emission, Monitor SPC for EPA, Pollution control board Requirements, also for car parking ventilation system.

ALVI AUtomation India, in association with Gas Alarm Systems Australia, introduce tested, trusted MSR Germany SPC-03-1110 Carbon monoxide, CO Stand alone pollution continuous monitor to meet statutory compliance of EPA, pollution control board requirements.

Steel plants, Coke Oven plants, Coal Processing plants, Blast Furnace, all need CO carbon monoxide monitoring system to ensure CO pollution, emission requirements for statutory compliance.

MSR SPC-03-1110 CO continuous monitoring system  is standalone system built in integral CO sensor cell which can monitor pollution, emission in the range of 0-300 ppm carbon monoxide.

FEATURES
Continuous monitoring
Integrated CO, Carbon monoxide gas sensor,  0-300 ppm.
Good resistance to poisoning
Long life expectancy
Modular design (plug-in, plugout technology both for sensor and PCB)
with display/LED/keyboard and internal buzzer
Reverse polarity protected, overload-proof and short-circuit-proof
(0) 4 – 20 mA / (0) 2 – 10V analog signal output
2 x relay outputs 30 VAC/DC, 0.5 A
2 x binary output, 30 VDC¸ 0.05 A
4 – 20 mA input for external transmitter
Poly carbonate, rugged impact resistance, glass fibre reinforced, UV protected, Outdoor housing versions IP65.

 

Gas Alarm Systems Australia ( ALVI Automation India) MSR Polygard Butane, C4H10, Monitor

Gas Alarm Systems(www.gasalarm.com.au) Australia in association with Gas alarm systems India (www.gasalarmsystems.in) are  pleased to introduce MSR Germany, Polygard Gas Detector for Butane, C4H10, LPG.

Butane, C4H10, LPG is  highly explosive, Combustible gas

Gas Alarm India (www.alviautomation.com)with Gas Alarm Systems  Australia (www.alvi.com.au) have MSR Gas Detector, Gas Analyzer, Gas Sensor, Gas Transmitter under MSR Polygard range to meet world critical safety standards for life and plant protection.

Our product range includes MSR microgard, MA-0-11xx, MC2-E11xx, ADT-x3-34xx, ADT-x3-11xx, SPC-x3-11xx, Polyzeta 2 for hazardous zone 1, zone 2 areas. it has IEC EX, ATEX certification with SIL 2.

All products and systems are manufactured in Germany , hence quality and reliability are assured.

Gas Redical Sensor Transmitter For Early Detection Of Gas Redical In Prevention Of Explosion And Fire In Explosive Storage And factory.

ALVI Automation Offer MSR Electronic, Germany Gas Redical Sensor Transmitter For Early Detection Of Gas Redical In Prevention Of Explosion And Fire In Explosive Storage And factory and Chemical Storage. ALSO
Indoor air quality (CO2+VOC) sensor transmitter includes digital
measurement value processing and temperature compensation for the continuous monitoring of
the ambient air to detect IAQ gas concentrations.
FEATURES
• Measuring range: 0-4000 ppm
• Technology: Bio Semiconductor
• Output: 4-20mA (standard) analog signal output, 0-10V DC (option), RS485 (optional) Continue reading “Gas Redical Sensor Transmitter For Early Detection Of Gas Redical In Prevention Of Explosion And Fire In Explosive Storage And factory.”

Ethylene Oxide Sensor, Transmitter, Detector Analyzer

ALVI AUTOMATION Gas Alarm India offer Ethylene Oxide sensor transmitter / detector/ analyser from MSR Electronic, Germany with following features:

  • Measuring range: 0-100% LEL (lower explosive limit), 0-100% Vol (analysis)
  • Technology: Pellistor / catalytic bead (flammability monitoring), Infra-red
  • Output: 4-20mA, 0-10V, RS485 modbus, Lon, BacNET
  • Enclosure: IP65, IP55
  • Certificate: UL 61010, UL 2075, ATEX EExd, ATEX EExn, CE
  • Mounting: wall mountable, duct mountable
  • Installation area: safe area, hazardous area, explosion-proof

Continue reading “Ethylene Oxide Sensor, Transmitter, Detector Analyzer”