Defence CAMP/TENT Protection System For Rapid Deployment Force

Gas Alarm Systems India(http://www.alviautomation.com) in association with Gas Alarm Systems Australia (http://www.gasalarm.co.au) offer MSR Germany Electronics Defence CAMP/TENT Protection System: For Rapid Deployment Force

APPLICATIONS:
Chemical, biological, Explosive Gases Terrorism Gas Threats Very Early Fire Detection Toxic Gas Fumes from bombs, missiles Air Quality in bunkers, shelters Energy Saving / Carbon Credit
Suitable for:
· Rapid Equipping Force in Forward Operating Bases
· Team Putting TENT System / ventilation system

Base camps and other forward deployed operating bases are highly vulnerable to both conventional and asymmetric/terrorist attacks. The frequency of attacks against Allied Forces during Operations Enduring Freedom and Iraqi Freedom indicate that current and future force deployments face an increased probability of such attacks.

The high casualty rates and disruption to operations emphasize the need for enhanced protection of deployed Allied Forces and other peace keeping operations. Conventional security measures provide little or no protection
from improvised lethal attacks. Previous attacks have exposed various weak points and shortcomings in current systems of Camp Protection.

Sensor Platform X (WSB2-X) is a module based software platform for sensor integration, data analysis, alert detection and alert response handling. It provides an automated surveillance system that monitors different kinds of sensors, performs sensor analysis and notifies and aids users in response to critical situations. WSB2-X is a unified management platform providing the customer with a customizable and easy scalable solution to collect physical
security sub-systems into one easy-to-manage system.

Its ability to integrate and manage third-party systems suits the needs of Military Camp Operations by consolidating information from various sources and presenting it in a way that is clear and draws an operator’s attention to the most critical information.

Our main focus areas are listed below, but through our partners we can expand the delivery to fit the customer’s requirements Our strategic partners (Australia, Germany) deliver products, systems and services such as:

Continue reading “Defence CAMP/TENT Protection System For Rapid Deployment Force”

Nitrous Oxide (N2O) Gas Detector

Introducting our All new Nitrous Oxide (N2O) Gas Detector by Gas Alarm Systems Australia.

Nitrous oxide (N2O), also called dinitrogen monoxide, laughing gas, or nitrous, one of several oxides of nitrogen, a colourless gas with pleasant, sweetish odour and taste, which when inhaled produces insensibility to pain preceded by mild hysteria, sometimes laughter. 

This product is a non-dispersive infrared gas sensor with integrated transmitter and pumped sampling system, for Nitrous Oxide (N2O) detection and measurement applications calling for a measurement range of 0-2000ppm.

Continue reading “Nitrous Oxide (N2O) Gas Detector”

Save Your Chemical Store Rooms from Hazardous Incidents Using Smart GSM Based System

Introducing our Smart GSM Remote Controller & Alarm System 

Typical applications
The voltage-free relays can be used with our other GC-series controllers to add remote functionality to a control system. The device can be paired with other controllers as well and a range of application for the device is mentioned below:
1. Security Alarm System applications;
2. Supervision and monitoring of alarm systems
3. Automatic monitoring system;
4. Vending Machines;
5. Pumping Stations;
6. Buildings and Real Estate;
7. Weather Station’s remote control and data logging;
8. River Monitoring and Flood Control remote control;
9. Oil and gas pipelines remote control and data logging;
10. Corrosion protection
11. Valve controls;
12. Wellheads;
13. Energy-saving, street lights control system;
14. Tanks, levels, temperatures, water leakage applications;
15. Transformer stations; 16. Unmanned machine rooms;
17. Control room application;
18. PLC and Automation System, M2M;
19. GSM Access Control System, GSM Gate Opener, etc.

GMS design

Click here to download the datasheet 

please reach us at info@alviautomation.com for more details 

GAS ALARM SYSTEM with Control and Monitoring Solution for Glass Plant Application

industry

ALVI Automation/Gas Alarm Systems designed engineered PLC & HMI based gas detection, monitoring  and control solution which include:

The Gas Alarm system components shall have similar features as specified below:
1. Gas controller cum display unit:
It shall be digital programmable logic controller (PLC) with CPU based, based on decentralized monitoring architecture with: 5 x slave controller (without display, with local digital output for alarm / Fan / Valve control etc) modules over RS485 serial interface TCP/IP or ModBus Communication, 1x Master Controller (with 10 inch colored touch-screen HMI LCD Display, with digital output for alarm / fan / valve control)
Display would show: gas concentration at each sensor, sensor status, sensor location, alarm status, system error, fault location etc Integrate able with BMS/ SCADA, Fire alarm system Configurable alarm threshold via touchscreen display password protected Simple English menu for configuration, with aux. power supply to sensor transmitters, wall mountable IP65 metallic / ABS fire retardant enclosure (non explosion proof), fire retardant panel wiring, 230VAC 1-phase power supply, with bench-top programming.

IMG_20161125_161442825panel 1

2. Hydrogen gas sensor/detector transmitter:
It shall be online, continuous monitoring of hydrogen in ambient air, measuring range: 0-2000 ppm H2, Electro-chemical sensor cell technology, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, SS 316 sensor cell enclosure with flash back arrestor and sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection. CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved EMC EN50270, EN 61000, ATEX, IECEX compliant

MSR PX2 Series Sensor Transmiter
3. Oxygen gas sensor/detector transmitter:
It shall be online, continuous monitoring of oxygen gas in ambient air, measuring range: 0-25% v/v O2, Electro-chemical sensor cell technology, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, SS 316 sensor cell enclosure with flash back arrestor and sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved EMC EN50270, EN 61000, ATEX, IECEX compliant

H2 ARB2 sesnor
4. C2H2 (Acetylene) gas sensor / detector transmitter:
It shall be online, continuous monitoring of acetylene in ambient air (in chloride containing background gases), measuring range: 0-100% LEL C2H2, reliable infra-red sensor cell with poisoing and etching immunity, self-compensating optics, pressure and temperature measurement, isolated RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated aluminum enclosure, SS 316 sensor cell enclosure, with back-lit LCD display, 24V DC powered, response time < 10 sec, IP65 ingress protection CSA/NRTL Class, Div 1, ATEX, IECEX, Group A,B,C,D T5 IECEx Ex d IIB + H2 T5 Gb, for Zone 1, 2

hydrogen-sensor-500x500
5. Silicon Chloride (SiCL4) (HCL) gas sensor/detector transmitter:
It shall be online, continuous monitoring of Silicon Chloride in ambient air (in chloride containing background gases), measuring range: 0-20 ppm SiCl4, reliable electro-chemical (galvanic) sensor cell with poisoing and etching immunity, self-compensating optics, pressure and temperature measurement, isolated RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated aluminum enclosure, SS 316 sensor cell enclosure, with back-lit LCD display, 24V DC powered, response time < 15 sec, IP65 ingress protection AYEX, IECEX, SIL2,  CSA/NRTL Class, Div 1, Group A,B,C,D T5
IECEx Ex d IIB + H2 T5 Gb, for Zone 1, 2

MSR_PolyXeta_mit_Display_RAL_7035_Alarm
6. GeCL4 gas sensor / detector transmitter:
It shall be online, continuous monitoring of GeCl4 gas in ambient air (in chloride containing background gases), measuring range: 0-20 ppm GeCl4 (calibrated against HCl), Electrochemical sensor cell technology, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, corrosion resistant SS 316 sensor cell enclosure with flash back arrestor and sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved, ATEX, IECEX, SIL2,  EMC EN50270, EN 61000 complian

ADT MC2 sensor

7. CL2 gas sensor/detector transmitter:
It shall be online, continuous monitoring of Cl2 gas in ambient air, measuring range: 0-20 ppm Cl2, Electro-chemical sensor cell technology, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, corrosion resistant SS 316 sensor cell enclosure with flash back arrestor and sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved, ATEX, IECEX, SIL2 EMC EN50270, EN 61000 compliant

CO Sensor Transmitter
8. CH4 (Methane) gas sensor / detector transmitter:
It shall be online, continuous monitoring of CH4 gas in ambient air (in chloride containing background gases), measuring range: 0-100% LEL ppm CH4, reliable infra-red sensor with poisoning and etching protection, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, corrosion resistant SS 316 sensor cell enclosure with sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved, ATEX, IECEX,  EMC EN50270, EN 61000 compliant

For more details please contact us or drop a mail to info@alviautomation.com we would be happy to serve you:)

Wish You All Many Many Happy New Year 2018

We Wish You & Your Family Many Many Happy New Year 2018.

Thank you for your association and trust on our organisation, it has been rewarding working with you all and may this new year bring  forth many such rewarding moments for us to share ..!

New year celebraation

We wish you luck, prosperity, health and look forward to continue serving you..!

Installation guidelines (FAQ) for Carbon Monoxide (CO) gas detectors in underground garages, parking houses and tunnels.

What are the mounting heights for CO gas detectors?

  • Carbon Monoxide (CO) gas has a slightly lower density than air. Recommended mounting height for Carbon Monoxide (CO) gas detector is 1.5 m above the floor.
  • According in garages are concentrations expected less 1%VOL and because of thermal an convection of gas the spreading is at whole area.
CO Gas Sensor
CO Gas Sensor

How many CO gas detectors are needed in a stationary installation?

  • There may exist some consultants, some local regulations or some country regulations, however, there are no absolute rules in determining the number of gas detectors and gas detectors location.
    (EN50545 CO 400m²).
  • The number of gas detectors are to be decided from case to case depending on the situation of the location you want to detect and monitor.
  • There are recommendations-guidelines (rule of thumbs).

One gas detector per 400 m2 (Coverage Area: 465 m2 to
930 m2 “Ideal Conditions” assumed using New Gas-DO-300-D) (i.e. one CO gas detector per 400 m2), plus additional gas detectors at the locations where gas leakage is likely to occur, preferably no farther than 1.5 meter (Mount at a height of 1.5 – 1.8 m above floor) where gas leakage is likely to occur.

What are the measuring ppm ranges for pre-alarm and warning alarm for  CO gas detectors?

CO detectors alarm levels:

  • Pre-alarm: 25 ppm.
  • Warning alarm: 35 ppm.
  • Fire alarm: 200 ppm

Measuring Range:0-300 ppm, Model no:GAS-CO-300-D

What is the gas sensor (cell) life time for CO gas detectors?

  • CO gas sensor (cell) life expectancy is 6-10 years, normal operation environment.
  • Fully sealed sensor cell, Gel type electrolyte not liquid type electrolyte with hydrophobic filter
  • If gas sensor (cell) is intensively exposed for fumes (gas) the life time is shorter.
  • If gas sensor (cell) is less exposed for fumes (gas) the life time can be longer.
Gas Sensor With Display Version
Gas Sensor With Display Version

Are the gas detectors needed to be re-calibrated?

  • The CO gas detectors are pre-calibrated before delivery.
  • The CO gas detectors are recommended to be re-calibrated on site or in-house once a year.

What to do when life time of gas sensor (cell) exceeded the expected life time ?

There are some different alternative choices, for examples:

  • New gas sensor (cell) can be ordered with re-calibration of the new gas sensor (cell) on existing PCB on site. For this alternative, the re-calibration instructions are needed to be followed very carefully. Recommended to be done of trained technicians.
  • Existing PCB can be returned to ALVI Group OR MSR and new sensor (cell) can be ordered.
  • The existing PCB can be factory pre-calibrated with the new sensor (cell).
  • New factory pre-calibrated gas sensor (cell) and PCB can be ordered.
  • Then the installer easily replace the existing gas sensor (cell) and PCB with the new factory pre-calibrated gas sensor (cell) and pcb. This is the easiest way of all above examples.
  • The exchangeable sensor transmitter cartridge is our new concept to re-look on the Gas sensor and we are pleased to introduce Our most popular, most miniaturized exchangeable Carbon Monoxide (CO) sensor cartridge with cutting edge German Technology.
Sensor Cartridge
Sensor Cartridge

Click here to download the datasheet

Feel free to contact us if you’re interested in the product or have any questions.

Or write us an e-mail in the contact form below straight away.

 

GasAlarm (www.gasalarm.co.in) is Restructured as ALVI Automation (India) Pvt Ltd (www.alviautomation.com) under Australasian strategy

  • Please note the company GasAlarm(www.gasalarm.co.in) India has been restructured under Australasian strategy with new company ALVI Automation (India) Pvt Ltd(www.alviautomation.com) (Please refrain from dealing with Vinod Gogoriya who is no longer associated with our new company). This company from now onwards will sell, service, maintain all MSR Germany Gas Detection systems, BECK, JOLA, FISCHER and JOVENTA products
  • We are the authorized distributor of Germany MSR, FISCHER, JOLA, JOVENTA and BECK. Since all the products are manufactured in Germany hence Quality and Reliability are assured
  • All MSR gas monitoring falls under critical safety system for life and plant protection. They need periodic service and calibration and ALVI Automation can assist you in the same

We are the authorized distributors and country representative of few German companies for India and can offer you gas sensor/analyser for all toxic (CO, AIR Quality, H2S, SO2, NO2 etc), flammable gases (H2, LPG, CNG, benzene etc) and oxygen, DP switch for air, water, aggressive media, DP Transmitter for air , water, aggressive media, Electric actuators, Level transmitter for water, diesel, float switch, process instrumentation for diff. pressure, pressure, level, temperature, Humidity etc. both for safe and hazardous area(ZONE 1 and ZONE 2) applications (IEC-EX, ATEX, SIL2 certified) of make MSR/Germany, FISCHER/Germany, JOLA/Germany, JOVENTA/Germany, GREISINGER/Germany and BECK/Germany range of products

ALVI Automation India Pvt Ltd is a Div. of ALVI Technologies Pty Ltd, Sydney-Australia, in operation since 2003. The company also operates under GasAlarm Systems. We are a group of experienced engineers, offering gas detection monitoring and control systems, process instrumentation, measurement & control products and automation solutions. We have been involved in several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. Our aim is to best serve and maintain long term relationships by providing most cost effective appropriate solutions. We are committed towards customer satisfaction through quality products and services. Our vast clientele proves the same. AAIPL derives competitive advantage from its excellent track record, product strategy, and the expertise of its team. The team is a group of more than 15 young dynamic energetic extremely talented industry professionals, who are qualified, trained, motivated and experienced enough to serve our customers well.

 

Our Primary Focus :

  • Critical Life Safety, Asset Safety, Asset Enhancement.
  • Process control instrumentation, process optimisation most cost effective way.
  • Energy saving, green house gas saving.
  • Pollution monitoring for better environmental control.
  • Industrial and Building Automation for better information flow, control.
  • Service, calibration, maintenance for asset protection, improvement (We take pride in this).
  • Training to customers, clients for effective use, operation of delivered system (we take pride in this too).
  • ALVI Automation (India) Pvt Ltd and Gas Alarm India in association with ALVI Technologies Pty Ltd , Gas Alarm Systems Sydney Australia, Deals with cutting edge Germany range products which includes :
  • MSR / Germany  gas sensors for H2, LPG, Hydrocarbons, LEL sensors, Methane, Hydrocarbons, Propane, Butane, LNG, CNG, Acetylene, Ethylene, Diesel fumes, CO2, VOC, SO2, H2S, HCN, HCI, NO, NO2 etc for hazardous(Zone 1 and Zone 2) and safe area application (IEC-EX, ATEX, SIL2, UL, CE certified)
  • JOLA Germany range of Liquid spill, liquid level, temperature Instruments with ATEX certified.
  • FISCHER / Germany range of Pressure, differential pressure, level, flow monitoring for air and liquid (Aggressive media) with (ATEX, SIL2 certified).
  • JOVENTA / Frakta Germany range of damper/Electric actuators.
  • GREISINGER / Germany Portable, standalone range of Liquid devices like PH, TDS, Conductivity, dissolved O2 etc and Gas measurement.
  • BECK / Germany range of Pressure, Differential Pressure, Switches and Transmitters including for ATEX hazardous area.

 

  • All these sensor/Field instruments are all based on German Technology, as all these sensors/Field Instruments are manufactured in Germany, hence quality and reliability are assured.

 

  • ALVI Automation (India) Pvt Ltd  (alviautomation.com) is involved in design, engineering, sales, service of Gas Detection Systems, Monitoring and Control Systems, PLC, SCADA, Building Automation, Factory/Industrial Automation, Instrumentation, System Integration and Control Panels. The Gas Sensors/Control modules are made by our associates MSR in Germany.

        The systems find wide application in:

CO/NO/NO2 monitoring in underground car parks for ventilation fan control meeting BCA, Leed/USA, AS 1668.2 (saves 60-80 % energy costs – investment paid back in 3-6 months). Run the fans only when required meeting the regulations, safety standards, energy saving/greenhouse gas saving requirement

Indoor Air Quality Monitoring (VOC/CO2) in buildings and controlling fresh air ventilation intake fans only when required (saves 60-80% energy costs)

Refrigerant Gas Leak Monitoring and alarm systems (R134a, R410a, Ammonia, CO2, LPG etc) for various refrigerants to meet GWP (Global Warming Potential) and AS 1677 refrigeration safety standards

Toxic Gas/Combustible Gas/Oxygen monitoring, control, alarm systems for plant, industry, human safety (Oil/Gas, Petro-chemicals, mining, Power Stations, Chemical Industries, water/waste water treatment plants)

Hazardous Area Gas Detection Systems for Oil/Gas Industries (very good potential in Myanmar) , IEC-Ex, SIL 2 certifiedPollution/Emission monitoring systems (some typical parameters are CO, CO2 etc)

Pollution/Emission monitoring systems (some typical parameters are CO, CO2 etc)

On Line, continuous gas monitoring analyzers for CH4, CO2 and some other parameters for bio-gas, land-fill gas, methane drainage (Coal Bed Mining Methane)

Fumigation gases monitoring in grain silos (phosphine, methyle bromide etc)CO2 monitoring in oil/gas CO2 capture and storage

  • In addition under ALVI Automation/GasAlarm, we provide instrumentation solutions like :
    1. Pressure, differential pressure, level, flow, volume Monitoring.
    2. Liquid leak, spill, level detection and monitoring including hydrocarbon spill on water.
    3. MSR Traffic – car parking, traffic navigation systems.(msr-traffic.de)

 

  • Our valuable customers are Siemens-India, Johnson Controls-India, Honeywell India, Schneider electric India, Adani-group, BASF, L&T, BHEL, HCPL-HMEL, HONDA, Denso-International, Bluestar, Greenheck etc are regularly buying from ALVI Automation (India) PVT LTD with that we are covering all industry segments, oil&gas, petro-chemical, chemical, power, water/waste water, landfills, mining, food & beverage, laboratories, refrigeration industries and Defence Organizations. We take pride in meeting customer.

SERVICE & TRAINING :

AAIPL provides information to engineers, professionals and everybody who is interested in Instrumentation, Process automation and control.

We provide services & training on Process Automation and Control, like DCS (Distributed Control Systems), BMS (Building Management System), PLC (Programmable Logic Controller), Batch Control, PID, Advanced Control, Measurement, HMI (Human Machine Interface), Measurement, Process Instrumentation, Industrial Automation Training. Our services programs are designed to minimize downtime, delays and unforeseen expenditures. With a comprehensive maintenance we make sure your instruments are always in top operating order. This gives you the peace of mind.

 

AFTER-SALES SUPPORT :

Maintenance is as important for instruments as for relations. AAIPL understands the importance of service required after sales to maintain the product performance. Our business has been built around providing the highest quality products and services. Our team is ever ready to serve the customers at their back and call. We can ensure a prompt service, immediate response and quick access. We pride ourselves on our product selection, expertise, customer service and technical support.

For more information please do not hesitage to contact us

Cost Efficient Standalone Toxic/Combustible Gas Monitoring and Control System

ALVI Automation/GasAlarm-India in association with ALVI Tehnologies Pty Ltd also trading as GasAlarm Systems presents the all new Cost Efficient Standalone Toxic/Combustible Gas Monitoring and control system, designed and engineered by ALVI

Features:

  • Simple mechanism for Gas detection
  • Unmatched precision and accuracy
  • Longer functional life

Technical Features of MSR Germany Sensor

  • 4 – 20 mA (or 2 – 10 V) analog output with selectable signal output for special mode, fault etc.
  • IP 54 Polycarbonate enclosure with features :
  1. Rough rugged impact resistant polycarbonate protection
  2. Glass fibre reinforced
  3. Ultra violet protection
  4. Knocks and vibration proof
  • Hardware & software according to SIL2(Safety Integrity Level) compliant development process
  • Digital measurement value processing incl. temperature compensation
  • Internal function control with integrated hardware watchdog
  • Data / measured values in μC of the sensor unit, therefore simple exchange uncalibrated <> calibrated
  • High accuracy, selectivity and reliability
  • Low zero point drift
  • Long sensor life time
  • Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration
  • Reverse polarity protected, overload and short-circuit proof
  • Housing for integration of the sensor unit
  • IP 54 version also available in IP 65 version

Technical Features of Stand Alone Display ad Monitoring Panel with  Builtin MSR Detector

  • 1x 4 digit 7 segment display or Touch Screen HMI 7” display to show MSR gas sensor reading and to set alarm output limit.
  • 1x Channel sensor analog inputs (4-20 mA or 2-10V from Sensor) (Customizable)
  • 2x Relays output  (Potential free relay contacts 230VAC, 1A) (Customizable) 
  • Inbuilt SMPS 24VDC
  • Operating Voltage : 230 VAC
  • Housed in plastic enclosure (also available in metal panel on request)
  • Keypad for setting
  • Rising / Falling alarm facility
  • User friendly
  • Fully pre-programmed as per customer requirement and ready to install

IMG_20170520_180220044

 

For more details please contact us

Intelligent parking at Sydney Markets By ALVI

Sydney Markets Limited owns and operates Australia’s largest markets, and is recognised as a world leader in fresh produce and community market management. The company provides an environment that supports competitive trade and effective distribution.
The facilities at Sydney Markets were specifically designed to create the best environment to receive, store, trade and distribute highly perishable fresh fruit, vegetables and cut flowers.
Now, due to the rising traffic all around the market, Sydney Markets needed a complete parking guidance system and finally purchased it at MSR-Traffic in order to improve finding free parking spots for their customers.

MSR Traffic by ALVI

Aerial view of Sydney Markets

The parking guidance system consists of several counting sensors for 5 different parking areas (entrance and exit lanes), road signs with LED-Displays (for all relevant intersections and entrances) and controllers with a central computer including the Software „ParkGard Control Center“. Onsite, a certified partner (Alvi) from MSR is doing technical support and commissioning – the installation itself is done by the customer.

MSR Traffic

MSR H2 Sensor Transmitter with GasAlarm Display Monitoring/Control Panel

ALVI AUTOMATION INDIA PVT LTD (www.alviautomation.com) a Div of ALVI TECHNOLOGY PTY LTD(www.alvi.com.au) also trading as       GasAlarm Systems(www.gasalarm.com.au) feels honour in introducing MSR Germany Hydrogen Sensor transmitter with GasAlarm Display Monitoring/Control Panel.

Description for MSR H2 sensor transmitter :

Analog transmitter for monitoring of gases and vapors in the ambient air. It is used for garages, chiller rooms and heating. The μ-Gard analog transmitter series MA is a reliable gas detector.

Application : 

For the detection of gases within a wide range of commercial applications Like :

  • Refinery, petrochemical and natural gas plants
  • Battery Rooms
  • Metallurgical
  • Chemical, medication
  • Environment protection
  • Electricity, communications
  • Fire protection
  • Utilities
  • Storage
  • Sewage disposal

FEATURES :

  • Continuous monitoring
  •  Low zero point drift
  •  Poisoning stable
  •  Long life sensor
  •  Easy maintenance / calibration
  •  Reverse polarity protected
  •  Overload protected
  •  4 – 20 mA analog signal output
  •  2-10V analog signal output
  • IP 44/54/65 protected enclosure

Description of GasAlarm Display Monitoring/Control Panel

ALVI Technologies/ ALVI Automation India / GasAlarm Sydney, Australia, Designed and engineered alarm display unit with  following features:

Best part is it can be customized according to the clients requirement 

Model no: GasAlarm-1200 

  • 1xChannel sensor inputs (4-20 ma)
  • 1×4 digit 7 segment display
  • 2xRelays output
  • 2xlevel alarm set
  • 24VDC power supply for sensor inbuilt of panel
  • Keypad for setting with preset value for alarm Regeneration
    1. 25%LEL for low Level Alarm (Changeable)
    2. 50%LEL for High Level Alarm(Changeable)
  • 230 VAC Power supply
  • Housed in wall mount IP 54 enclosure

Click here to access the datasheet

WISH YOU AND YOUR FAMILY HAPPY COLORFUL HOLI…!!!!

Dear All,

ALVI Team India/Australia takes pride to wishing you and your family a very happy and colorful holi..!!!!

Celebrating the colors of our beautiful business relationship…!!!!!
We wish you and your family all the bright hues of life. Have a colorful Holi… !!!!!

 ALVI Holi Wishes

MSR Germany Hydrogen/Combustible Sensor with Custom Built ALVI Display in PPM, %LEL and %Vol With Password Protection

ALVI AUTOMATION INDIA PVT LTD (www.alviautomation.com) a Div of ALVI TECHNOLOGY PTY LTD(www.alvi.com.au) also trading as       GasAlarm Systems(www.gasalarm.com.au) feels honour in introducing MSR Germany Hydrogen/Combustible Sensor with Custom Built ALVI Display in PPM, %LEL and %Vol With Password Protection.

Description for MSR H2 sensor transmitter :

Analog transmitter for monitoring of gases and vapors in the ambient air. It is used for garages, chiller rooms and heating. The μ-Gard analog transmitter series MA is a reliable gas detector.

Application : 

For the detection of gases within a wide range of commercial applications Like :

  • Refinery, petrochemical and natural gas plants
  • Battery Rooms
  • Metallurgical
  • Chemical, medication
  • Environment protection
  • Electricity, communications
  • Fire protection
  • Utilities
  • Storage
  • Sewage disposal

FEATURES

  • Continuous monitoring
  •  Low zero point drift
  •  Poisoning stable
  •  Long life sensor
  •  Easy maintenance / calibration
  •  Reverse polarity protected
  •  Overload protected
  •  4 – 20 mA analog signal output
  •  2-10V analog signal output
  • IP 44/54/65 protected enclosure

Description for Custom Built ALVI Display in PPM, %LEL and %Vol With Password Protection

ALVI Technologies / GasAlarm Sydney, Australia, Designed and engineered alarm display unit with  following features:

Best part is it can be customized according to the clients requirement 

Model no:  ALVI-DISP-1200

  • 1 Analog input (4-20mA, from MSR transmitter)
  • 2 Digital Outputs (potential free relay contacts, 230 VAC, 1A)
  • Touch screen (HMI) for settings
  • User friendly
  • 2 level alarm set (rising/falling)
  • Housed in wall mount Metal enclosure
  • Supply voltage: 230 VAC
  • 230-24VDC SMPS
  • Fully pre-programmed as below and ready to install
    1. Hydrogen reading will be show in PPM
    2. Hydrogen LEL limit is 4% Vol so display range will be 0-40,000 ppm (1% Vol= 10,000 ppm)
    3. Alarm 1 limit will be set at 10% LEL (4,000 PPM) : changeable
    4. Alarm 2 limit will be set at 20% LEL (8,000 PPM) : changeable

Click here to access the datasheet