Blog

Carbon Monoxide Sensor Transmitter

We  ALVI Automation India Private Limited in association with  GasAlarm Systems  company based in Sydney, Australia (www.gasalarm.com.au) specialising in gas detection & monitoring solutions feel pleased to introduce our new and and best reliable Carbon Monoxide Sensor Transmitter  GAS-CO-300-X

Introducing the GasAlarm Systems GAS-CO-300-X

Most cost optimum sensor transmitter  for carbon monoxide – application in car park ventilation fan control, coal mining , coal handling plant, coal washeries , boilers , steel plants, pharmaceutical anywhere gas and coal combustion takes place – best very early fire detection due to gas radicals detection – smouldering fires.

 

Specifications in Detail:

  • 24VDC power with 4-20mA output (current loop)
  • 0-300PPM Carbon Monoxide measuring range
  • Long Life – ≥ 6 years (Life Expected  ≥  10 years)
  • High Accuracy –  ± 3ppm
  • Wiring – 2 wire system (reduce wire cost)
  • Onboard potentiometer for “zero” adjustment
  • Onboard potentiometer for “gain/span” adjustment
  • Multimeter connections for measurement during calibration
  • With “D” enclosure option, rated at IP65
  • With “F” enclosure option, rated at IP44
  • Calibration Interval – 12 Months
  • Easy to use with low maintenance  cost .

Click here to download the datasheet

For more query and enquiry please contact us : Info@alviautomation.com 

The PERFECT Low Cost CO Detector for the EMERGING Countries

We GasAlarm Systems in association with ALVI Automation India Private Limited, is a company based in Sydney, Australia (www.gasalarm.com.au) specialising in gas detection & monitoring solutions.

With over 40 years of experience in the industry we like to think we know a little about the industry and how its changed over the decades.

What we found lacking was good quality reliable products which were low cost, especially for the developing/emerging markets & countries.
So, we’ve taken it upon ourselves to slowly introduce such products one by one.

We dedicated to start with the most common product in gas detection worldwide, the humble CO sensor.
Countless brands, models & technologies exist however we feel ours has hit the spot when it comes to the all-important price and performance ratio.

We’ve kept it extremely compact!
We’ve kept it extremely simple!

We’ll be honest, our aim is to sell this product at extremely low margins however in large quantities.
Thus, ensuring you, the customer keeps buying and sees the value add in the product locally.

Introducing the GasAlarm Systems GAS-CO-300-X

The all-in-one sensor/transmitter is made in Germany under an OEM exclusive agreement for us.
It uses an electrochemical sensor cell. NOT semi-conductor or MEMs semi-conductor like other cheap products!
It offers an industry standard measuring range of 0-300 ppm.
It runs on an industry standard 2 wire 24VDC current loop with a 4-20mA output.
It has 2x onboard potentiometers for future on-going calibrations, A zero & a span/gain pot.

To save you costs on freight & to help you with your own branding, we would be happy to sell these without an enclosure/housing.
You can then mount them locally in your own enclosure with your branding & part number!

In a small tray measuring 28cm (11in) x 19cm (7.5in) x 4cm (1.6in) we can fit 10x units without enclosures! We would add extra padding & another carton before shipping. Of course, if needed we can supply these with an enclosure as well.

Specifications in Detail:

  • 24VDC power with 4-20mA output (current loop)
  • 0-300PPM Carbon Monoxide measuring range
  • Long Life – ≥ 6 years (Life Expected  ≥  10 years)
  • High Accuracy –  ± 3ppm
  • Wiring – 2 wire system (reduce wire cost)
  • Onboard potentiometer for “zero” adjustment
  • Onboard potentiometer for “gain/span” adjustment
  • Multimeter connections for measurement during calibration
  • With “D” enclosure option, rated at IP65
  • With “F” enclosure option, rated at IP44
  • Calibration Interval – 12 Months
  • Easy to use with low maintenance  cost .

For more query and enquiry please contact us : Info@alviautomation.com 

Ammonia Detector Transmitter

Ammonia is a Toxic, colorless and pungent smelling gas which affect  living bodies if ammonia gas present in air, to stop any hazardous and panic incident we must use Ammonia Detector Transmitter  in the primieces  where ammonia gas or gas container present .

Exposure to high concentrations of ammonia in air causes immediate burning of the eyes, nose, throat and respiratory tract and can result in blindness, lung damage or death. Inhalation of lower concentrations can cause coughing, and nose and throat irritation to stop all these panic incident we need to use Ammonia Detector Transmitter in the place where there is chance of leakage of NH3 ammonia gas .

This Ammonia Detector detect the leakage of ammonia and immediately and Transmit the signal to actuate  the alarm and close the ammonia gas supply line.

Mosty in North India (UP, Bihar, MP, Rajasthan , Delhi NCR, Punjab, Mumbai Etc.) we come across the news of leakage of Ammonia gas (Ammonia Gas Rishav) from the cold , Fruit Ripening Chamber and Ammonia factories  and this causes the Death of number of innocent people working in the primieces and also who lived near to the spot of incident due to inhaling of ammonia gas present in air due to this leakage .

Recently in 2018 till now 3-4 cases of Ammonia Gas leakage took placed  in  Kanpur, Allahabad and Punjab where numbers of people suffered and died along with numbers of Animal and Birds .

To stop all these types of panic incident by using MSR Germany  Ammonia Leakage Detector Transmitter in such places to ensure the safety of life of your worker and nearer .

We at www.alviautomation.com working in the field of Gas Leak Detection System and our Motto is save the Environment for all, for this we are committed to serve you all through our experience, supply, support & consultancy .

For any query and enquiry please feel free to contact us – Info@alviautomation.com.

 

Best Carbon Monoxide (CO) Sensor Transmitter

Best Carbon monoxide(CO) and Very early smoke & fire Sensor (VEFSA) Transmitter having benefits of High Accuracy, Long Life, in  Budgetary  Price .

Better monitor CO and CO+ radicals  which will solve the purpose of fire & Smoke monitoring as well as CO monitoring.

Best Uses for  :-

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smouldering fire and smoke detection
  • VESFA system (very early smoke and fire alarm)
  • Parking area, garages, chillers rooms and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant,coal yard, thermal power plants, flour mills, powder industries etc.

specifications:

  • Make :  MSR Germany  (Made in Germany)
  • Sensor Model: MA-0-1110-F-B
  • Measuring Gas: Carbon Monoxide, Enhanced CO+ radicals
    Detection.
  •  Sensor element (cell): Electrochemical Diffusion, Electrolyte type Gel Based (no leak, no membrane rapture, no orientation problem & no false alarm )
  • Plug in type Sensor transmitter. (Easy maintenance, easy returnable in case of any fault in sensor or transmitter)
  • Measuring Range: 0-300 ppm (Standard)
  • Quick response and fast recovery to Zero
  • Poisoning Stable.
  • Over flooding protection
  • Connection: Two wire sensor.
  • Accuracy: ± 3 ppm.
  • Repeatability:
  • Response time T90:- ≤ 50 Seconds.
  • Warm up time (First Time):- ≤ 3 Min.
  • Protection Class: IP 44 Enclosure (Good for indoor application), Also available in IP54 and IP65 Enclosure (For outdoor application)
  • Stability & resolution:≤ 50 Seconds.
  • Sensor life expectancy: ≥ 5 years (Site feedback ≥ 10 years)
  • Calibration Interval : Yearly
  • Sensor Coverage Area:700 m2 to 750m2 (depends upon the country specific parking ventilation standards.)
  • Analog output signal : Standard: 4-20 mA Linear Output (2-10 Vdc)

For more details and query Please contact us : info@alviautomation.com

For the technical datasheet please click here : Datasheet

Joventa Electric Damper Actuator for Thermal Power Plant

We are pleased to announce Joventa Electric  Damper Actuator DA1.S which is the most demanding actuator  in the Thermal Power Plant of India.

The JOVENTA STANDARD electric damper-actuator DA1.S  series is designed to operate air dampers in ventilation and air conditioning systems. The compact design and universal adapter fitted with limitation of rotation angle make this JOVENTA actuator highly versatile.

Key Features :

  • Model no : DA1.S, 24V with 2 auxiliary switches
  • 16 Nm torque
  • Control signal input: 2 or 3 point
  • Degree of protection: IP 54 (cable downwards) also available in IP 65 .
  • Running time : 80s – 110 s
  • Angle of rotation/working range : 90° (93° mech.)
  • Supply 24V DC/AC
  • Frequency : 50-60 Hz

For the technical datasheet please click on : Datasheet 

For any query and enquiry please contact us : info@alviautomation.com

 

SIL 2 Approved Pressure Instruments

We are glad to introduce SIL 2 approved pressure instruments in Austrlasian countries.

ALVI Group India/Australia   Pleased offers SIL 2 Approved Differential Pressure Transmitter, Switch,  Pressure Transmitter, Pressure Switch,  Level Transmitter,  Level Switch, Gauge and monitoring field instruments for use in the wide area of industries including process industry, building, MEP, HVAC, oil & Gas, chemical, food processing, nuclear, petrochemical, hydro, power plants etc.

Model No : MS11, DS11, DS13, DS21, DE44, DE45, NK10

SIL 2 approved Pressure Transmitter

For any query please feel free to contact us : Info@alviautomation.com 

Carbon Monoxide (CO) Detector – Best German Technology

We are pleased introduce  Carbon Monoxide (CO) Detector – Best German Technology  in most economical cost compare to the  market price of other competitor brand .

As we all know that Carbon Monoxide  gas is also called silent – invisible killer as CO doesn’t have smell, colour  or tase .

Any time you burn something—like gasoline, natural gas, wood, oil, propane, or charcoal—carbon monoxide is released into the air. In outdoor spaces, this usually isn’t a health hazard because there is enough area for the CO to dissipate, so particles never amount to a toxic level. The danger comes when carbon monoxide is released in a contained area like your home, RV, or garage, Car Park, Coal Mines, Industries.

It is most important for everyone to install CO detector in their premises as mentioned above it is best security system of their life and property as CO detector can also intimate you if there is any fire in the premises .

For any enquiry or query please feel free to contact us  in  our mail id – info@alviautomation.com

Environmental Safety – Gas Leakage Monitoring & Control Systems

Everyday we come across a news of hazardous incident of fire in hotel, resident, industries, etc, the tragedy happen due to the leakage of combustible/explosive gases or sudden electrical spark and the carelessness of management systems.

On 31st May we came  across a news that Gas leakage causes fire in Jindal factory in Narol area in the evening on Wednesday 30th May the incident took place at the godown of the factory which had storage of Hydro, indigo, caustic soda, pigments and starch. Earlier, in four different incidents, there were reports of gas leakages.

We all know that in market there is lots of gas leak detection and early fire detection system which stop the horrible incident by intimating the managements by actuating  Alarm , Closing  gas Supply System , sending Messages to the concern  team & many more options .

We request you to put your concern towards the Gas leakage,  life, property and Environmental issues and stop these kind of painful incident in our country .

We at www.alviautomation.com promise you to provide you best German Technology for the safety of your  premises.

We feel pleased if we can assist you, guide you and provide you our best consultancy and product services.

Gas_Detecton_System #Stop_fire_Incident #Stop_Hazardous_Tragedy #Save_Life #Save_Energy #Save_Environment & #save_money ..!

CO Sensor Transmitter – CO Gas Effect on Health

Carbon Monoxide gas is colourless, odourless and tasteless gas that is slightly less dense than the air . It is toxic to hemoglobic animals when encountered  in the concentration above 35 ppm .

CO Gas produce due to partial oxidation of carbon containing compounds; it forms when there is not enough oxygen to form CO2 .

It may produce due to burning of wood (Smoke), from bike, auto, and any vehicle  etc.

It affect human body as per the level of gases in surroundings / environment as defined  in below table –

Effect of CO in Health

People need to be aware of CO gas leakage/ presence in the primicess cause some time it is more hazardous than we imagine .

We at www.alviautomation.com  committed to provide you complete solution of CO Gas Detector and Control Monitoring Systems .

For any query and gas leak detector please feel free to contact us .

 

Fire Protection System By Frakta/Joventa GmbH

ALVI AUTOMATION present to you a revolution product by Frakta/Joventa GmbH.

Frakta Logo

  • The company Frakta Vertriebs GmbH based in Rohrdorf ( in Nagold ) is a family.
  • We are your specialist when it comes to easy – to use systems and applications for fire protection and smoke extraction in buildings
  • Our motto «Building a Safer Tomorrow» motivated us, offer our customers the easiest, safest, most flexible and tailored to their project solution

The philosophy FRAKTA

  • Easy, easy, easy!
  • For everybody who is working with our systems!
  • Open and flexible
  • Our products are based on standard protocols (BACnet / Modbus)
  • Thanks to our modular product range can we offer complete system solution or
  • The products can be combined or integrated with/in any third-party manufacturers. Frakta provides the necessary information on request
  • Modern and Up to Date
  • Our solutions comply with the latest technology standards
  • Commissioning is simple and the user interface ( MMI ) intuitively

Our Goal

  • Lowest total cost of the installed system (lowest total installed costs!)
  • planning
  • installation and commissioning
  • operation
  • Elimination of possible error sources at planning, installation, commissioning and maintenance
  • Simplify and speed up the work needed throughout the whole project process

FRAKTA System for  Fire & Smoke Extraction Dampers

Customer Requirements

  • System
  • Specification / Subscription
  • Handling
  • Installation
  • Commissioning
  • Clear display / MMI
  • Test run possibilities
  • Logging and reporting
  • Maintenance
  • Verification of each project step
  • High flexibility
  • Completion of components also during installation possible
  • Simple upgrade
  • Cost efficient
  • For new projects and retrofit jobs
  • Use of standard communication protocols

Market Requirements

Controls Companies:

  • A simple implementation in a BMS or a Fire Alarm Systems
  • The autonomous operation for the F&S application
  • Visualization of all F&S dampers and devices possible
  • Standard interfaces
  • Standard reporting

Implementation / Allocation FRAKTA Solutions

FRAKTA 5i

Advantages FRAKTA Systems

  • Easy integration into building automation system through standard interfaces
  • No gateways or additional integrated protocols needed
  • Clearly defined field of responsibility
  • Easy planning and subscription
  • Less wiring effort, reduction in wiring mistakes and reduction of fire load
  • Full transparency of all installed devices
  • Much less space in controls cabinet needed if any
  • Easy extendable
  • All-inclusive package for the application
  • Use of pre-programmed and tested controllers
  • No license fees

System Layouts Fire Safety and / or  Smoke Extraction Application

m FRAKTA 7

FRAKTA 2 FRAKTA 3 FRAKTA 4

Summary Solutions by FRAKTA

  • Universal Solution «Fits All»
  • No matter if you have a 30 fire and/or smoke extraction dampers or 200 and more with the FRAKTA solution we can offer you great flexibility
  • Our solution can be connected to all F&S actuators available in the market (e.g. Joventa, Belimo, Gruner, Siemens etc.)
  • The pre-programmed applications in the M200 / M60 controllers are unique and do not exist to this extent in the market
  • Modular solution based on standard protocols
  • We offer an open platform based on Modbus or BACnet.
  • Regardless if you want to have the M200 or M60 controller or the field controllers FC24 or UFC devices and integrate them into one of your controllers – we supply you with all necessary information regarding interfaces etc.
  • The system M60 can be used for the fire or smoke extraction application. Configuration via dip switch.
    System M200 for fire application.
  • The Systems M60 / M200 can be integrated into any Modbus or BACnet controller
  • Increase your added value
  • Universal System Link between fire or smoke extraction dampers and any Modbus or BACnet system or analog control – all in one product!
  • Easy to choose – one product for (almost) all applications
  • reduce the variety of products in stock
  • Remarkable saving potential

For more details please contact us or mail us at info@alviautomation.com 

Hydrogen / Flammable Gas monitoring system in battery, inverter charging room – to prevent explosion

ALVI Automation also trading as GasAlarm in association with ALVI Technologies Sydney Australia brings to you a complete Automation solution along with the best selling product in terms of quality and reliability MSR GmbH Hydrogen sensor transmitter.

Hydrogen sensor transmitter specifications:

  • Should have Catalytic (pellistor) based sensor cell, with catalytic bead
  • Should have a measuring range of minimum 0-100% LEL (lower explosive limit) for flammability monitoring, with no poisoning effect of background gases
  • Should have a catalyst capable of providing flashing point, at a lower temperature, for the sensor cell.
  • Should have microprocessor-based value processing with temperature, vibration, moisture, humidity etc compensation reading
  • Should have high accuracy, high repeatability, high reliability
  • Should be a 3-wire connection for power supply and signal output.
  • Should have jumper selectable analog output: 0-10V, 2-10V, 0-20mA, 4-20mA
  • Should have linear and proportional signal output.
  • Should have low response time: t50 < 3 s; t90 < 10 s /methane
  • Should have Low voltage operation: 24V AC / DC
  • Should have low power consumption: 35 mA, max. (0.85 VA)
  • Should be wall mountable without need of further mounting brackets etc.
  • Should have replaceable sensor cell and PCB for easy service and replacement
  • Should have life expectancy of > 3 years, replaceable sensor cell
  • Should capable of mounting in any direction, with no effect on performance, output and life of these sensors (no orientation problems)
  • Should have poisoning protection, against background gases, lead vapours, dust etc
  • Should have overflooding protection
  • Should have reverse polarity and short circuit protection
  • Should capable for field calibration
  • Should have minimum IP65 protection
  • Should have vibration protection (High frequency, low amplitude) and knock protection (high amplitude, low frequency)
  • Should have fast response time
  • Should have IMMUNITY TO RF/FM INTERFERENCE as per the guidelines of EMC- Directive 2004/ 108/ EEC
  • Should be Approved according to EN 61010-1; ANSI/UL 61010 1; CAN/CSA-C22.2 No. 61010-1
  • Should have Digital method  for calibration
  • Should have enclosure flammability in accordance to UL 94 V2

Smart Central monitoring cum control system:

 

  • Should be based on PLC or microprocessor based system with pre-defined logic retention capacity.
  • Should have LCD Display
  • Should be able to expand analog input channel with help of slave or expansion module. No need to replace or change whole monitoring system
  • should have free configurable set points at every channel input
  • Should have the facility to temporary disable any channel with a key press, for maintenance mode etc.
  • Should have sufficient potential free (230VAC, 5A) relays. Should able to expand the number of relays with help of slave/expansion modules.
  • Relays should capable of the soft program, with one-to-one, one-to-many, many-to-one configuration with any channel set-points.
  • Should be provided with contactor arrangement for operation, protection of exhaust fans, etc
  • Should have overload protection arrangement
  • Should have fault LED
  • Auto-diagnostic watchdog with built-in error code, fault LED indication informing about the type of system error/fault
  • Should have a password for protection against any unauthorized system access.
  • Simple English Menu driven (system error, status alarm, status relay, MP parameter etc)
  • Configurable relay parameters: energized, de-energized, latching, non-latching
  • Should have provision/option for BMS integration via a digital network.

20171101_182913

Control & warning logic:

H2 concentration Action
0-15% LEL No action. Display readout
>25% LEL (or as advised by the client) Start exhaust system (to reduce gas concentration)
> 50% LEL (or as advised by the client) Switch on Flasher & Alarm system (to start evacuation)

For more details please contact us or mail us at info@alviautomation.com 

Level, Spill, Leak, Moisture Detectors By JOLA GmbH (for Hazardous Areas):

LEVEL MONITORING:

JOLA Floating Switches and Immersion Probes:
Mercury-free floating switches and immersion probes Controlling devices
with ball-operated micro-switch, for signalling or control of liquid levels

JOLA Float Switches SM Ex:
SM… float switches Control units with rod operated micro switch
for liquid level indication or control of liquid levels for electrical systems
and for pneumatic systems

JOLA Immersion Probes TSR Ex:
For signalling or control of liquid levels. For use in low viscosity, nonadhesive liquids that are free of solids and do not attack the component
materials

JOLA Magnetic Switches and level indication with TAPS:
Magnetic switches, level indicators with taps and level controllers with builtin magnetic switches for level control in tanks

JOLA Continuous Level Measurement (Float Method):
Continuous liquid level measurement with TSQ 4-20/… and TSK 4-20/…
liquid level indicators for remote transmission of liquid levels using
the float method
JOLA Continuous Level Measurement (Bubbler method):
PKG 4-20 Liquid Level Transmitter for continuous level measurement
for remote transmission of liquid levels using the air bubbler method
Due to the force of gravity and as a function of the specific gravity of the
liquid, the pressure at the bottom of a tank is proportional to the liquid level
in the tank. The pressure corresponding to the liquid level is measured by
means of an immersion bell mounted just above the bottom of the tank or
an immersion tube which is open at the end and suspended slightly above
the bottom of the tank. An air pump integrated in the liquid level
Transmitter pumps air into the bell or tube via a hose for 10 seconds every
50 seconds. The air pressure at the bottom edge of the immersion bell or at
the end of the immersion tube following the injection of air is equal to the
pressure generated by the liquid. The air pressure in the immersion bell or
immersion tube is measured by a pressure sensor integrated in the liquid
level transmitter and converted into a load-independent current signal of
between 4 and 20 mA via an integrated current loop transmitter.

JOLA Conductive controlling devices (water, acids etc):
For automatic control, regulation and signalling of liquid levels Electrode
controls are used for the automatic control of pumps or electromagnetic
valves as well as overflow or run-dry protection in wells or tanks with
conductive liquids. The liquid levels are monitored by electrodes which give
switching commands to the electronic relay if they come into contact with
the liquid.
JOLA Capacitive Level Controllers (water, acids, oils, solvents):
For automatic control, regulation and signalling of levels of conductive and
non-conductive liquids or pourable bulk goods The function of the proximity sensors is based on the change in capacity of the electrode located in the active surface of the proximity sensor. This change in capacity is generated by proximity or contact of the liquid/pourable bulk good
to/with the active surface of the proximity sensor.

JOLA Protection and Alarm Relays:
Protection relays: for connection of binary sensors (e.g. Jola floating
switches or Jola immersion probes) or for connection of Namur-sensors
(e.g. inductive or capacitive proximity sensors)
Alarm relays: for connection of several relays to one alarm relay or
for connection of binary sensors (e.g. Jola floating switches or Jola
immersion probes)
JOLA Liquid Leaks or Spills:

JOLA Leakage Detector Leckstar (Conductive e.g water, acids):
For use in conductive liquids like water, acids. Utilises plate electrodes,
rod electrodes, suspension electrodes with cable breakage monitoring. As
soon as a trace of a conductive liquid creates a conductive path between
the two electrode plates, a control current flows from the corresponding
electrode relay. The latter is then energized and a contact is made via the JOLA Leckstar 101 Relay.

JOLA Leakage Detectors Leckmaster (Capacitive e.g for oils, solvents,
fuels):
For conductive and non-conductive liquids; can basically be used for the
detection of all low-viscosity liquids for such tasks as signalling the
presence of fuel oil on the floor of a tank room or in a collection tub
located underneath a fuel oil burner. The COW/L and OWE 2/C sensors
are designed for connection to the Leckmaster 101relay.

JOLA Leakage Detectors Leckwatcher (Conductive e.g water, acids):

JOLA Types of detectors:
Point sensors: leakage detectors which can detect leakage at a specific point: plate electrodes, wall-mounted electrodes, rod electrodes, suspension electrodes
Line sensors: leakage detectors which can detect a leakage over the entire length of their electrode leads having cable electrodes or tape electrodes
Surface sensors: leakage detectors which can detect a leakage over the entire surface area of a network of interconnected electrode leads:
– sleeve electrodes

JOLA Leakage Detectors Leckwatcher (Capacitive e.g oils, solvents, fuels):
JOLA Types of Detectors:
JOLA Capacitive suspension sensors with stainless steel housing
JOLA Capacitive suspension sensors with plastic housing
JOLA Capacitive plate sensors with plastic housing
JOLA Leakage Detectors Liqui-Switch (Conductive e.g water, acids)
Designed to signal the presence of a conductive liquid caused, for example, by burst pipes. Plate electrodes should only be used in normally dry environments. They must be installed on the floor in such a way that the sensor side faces downwards and the label side upwards.
JOLA Leakage Detectors Liqui-Switch (Capacitive) for oils, fuels, solvents:
For signalling the presence of a non-conductive or conductive liquid. Can in principle be used for all low-viscosity media – e.g. for signalling the presence of heating oil on the floor of a tank room or in a collection tub located underneath a heating oil burner. Capacitive suspension sensors should only be used in normally dry environments.
JOLA Leakage Detector L-Pointer (Conductive):
The conductive leakage detectors can only be used for the detection of leakage of conductive liquids like water, caustic soda, hydrochloric acid, nitric acid, ferric chloride, and similar liquids.

JOLA Leakage Detector L-Pointer (Capacitive):
For oils, fuels, solvents for extra low voltage SELV or PELV, for connection to NAMUR isolation amplifier or NAMUR fieldbus terminal. The capacitive leakage detectors are primarily designed for the detection of leakage of nonconductive liquids but can also be used for the detection of conductive liquids.
JOLA Floating Electrodes for Oil in Water:
For detection of a thin layer of non-conductive liquids with a lower specific gravity on top of conductive liquids with a higher specific gravity. Floating electrodes are designed for use only in pits, reservoirs, and pump shafts, separator plants for light liquids or similar areas.

 

OTHERS:
JOLA Moisture or Condensation Detector (cooling ceilings):
FTS/KO-1 film sensor for cooling ceiling controller. The FTS/KO-1 film
sensor is a PCB film which can be stuck to a copper pipe or an even
metal surface. The back of the film sensor is coated with an adhesive
agent and a protective film. The film sensor is equipped with parallelrouted
printed conductors (sensitive surface) which are gold-plated for
improved surface protection. The sensor acts as a conductivity measuring
cell. The conductivity is measured using alternating current in order to
prevent corrosion and polarisation effects. The sensor is available with
connected 3-metre long thin white wire. Other connecting line
lengths are available on request
The film sensor should be installed at the point in the cooling ceiling
system where moisture is most probably expected to occur.
JOLA Limit Switches with ball operated micro-switch(RK, RAT-Ex):
The limit switches RAT/./E/Ex-1G are recommended for use wherever the
use of conventional flameproof encapsulated limit switches is difficult due
to demanding ambient conditions. Such conditions include, for example,
wet or soiled environments. The specific limit switch RAT/./E/Ex-1G is
mounted via a continuous borehole in the head section of the unit.
The limit switches RAT/./E/Ex-1G are fitted with a micro-switch
(changeover contact) as electrical switching element, and this element is
activated by an internal metal ball. Switchover takes place when the limit
switch is positioned approx. 17° +/- 8° above or approx. 3° +/- 3° below
the horizontal plane. The model RK is external mountable limit switch.
The limit switches are not suitable for use on rotating shafts.
Limit switches RAT/./E/Ex-1G II 2 G Ex d IIB T6 or T4

JOLA Magnetic Switches MBK Ex:
in protection class “intrinsically safety”
EEx ia IIC T6, T4 or T3 for use in intrinsically safe circuits in
potentially explosive atmospheres in categories zone 0, 1 or 2; EC type
examination certificate INERIS 04ATEX0096
Needs Jola protection relay KR 5/Ex I (M1) / II (1) GD [EEx ia] I / IIC

For more details please contact us or mail us at info@alviautomation.com 

Click here to download for all JOLA GmbH range of products 

Put your concern towards the gas leak incident in plant and industries

#Gas_Detecton_System #Stop_fire_Incident #Stop_Hazardous_Tragedy #Save_Life #Save_Energy #Save_Environment & #save_money ..!

Everyday we come across a news of hazardous incident of fire in plant,  hotel, resident, industries, etc, the tragedy happen due to the leakage of combustible/explosive gases or sudden electrical spark and the carelessness of the management and security systems.

we all know that in market there is lots of gas leak detection and early fire detection system and gas leak detection systems which stop the horrible incident by intimating the managements by actuating  Alarm, locking gas Supply System or can say close the solenoid valve , messages & many more options are there .

But sadly saying that in India 60%people who needs fire and gas leakage monitoring and control system in their premises are not using these system in their premises .

We request you to put your concern towards the security system, Life and Environmental issues and stop these kind of painful incident in our country.

For all types of gas detector process instruments  energy saving & field instruments you can contact us

We feel pleased if we can assist you, guide you and provide you our best consultancy and product services.

We at Alvi Automation promise you to provide you best German Technology to save your Life, Money, Plant, Industries, Building etc. ..

ALL FISCHER MESS- UND REGELTECHNIK PRODUCTS

ALVI AUTOMATION (India) Pvt Ltd offers Differential Pressure-measuring, Pressure, Level, Gauge and monitoring field instruments for use in the wide area of industries including process industry, building, MEP, HVAC, oil & Gas, chemical, food processing, nuclear, petrochemical, hydro, power plants etc.

FiSCHER PRESSURE Gauge,Transmitter and switch: 

Product Discription  Model no
DIAL PRESSURE GAUGE / BOURDON TUBE / FOR GAS / STAINLESS STEEL DA55
DIAL PRESSURE GAUGE / BOURDON TUBE / PROCESS / FOR GAS MA12
DIAL PRESSURE GAUGE / BOURDON TUBE / PROCESS / FOR GAS MA13
DIAL PRESSURE GAUGE / DIAPHRAGM / FOR GAS / CORROSION-RESISTANT MA15
DIGITAL PRESSURE GAUGE / DIFFERENTIAL / FOR GAS / PORTABLE MA25
DIGITAL PRESSURE GAUGE / FOR GAS / PORTABLE MA30
ANALOG PRESSURE GAUGE / BOURDON TUBE / PROCESS / FOR GAS MA32
DIAPHRAGM SEAL WITH THREADED CONNECTION / FOR PRESSURE GAUGES / FOR THE FOOD INDUSTRY MD03
DIAPHRAGM SEAL WITH FLANGE CONNECTION / FOR PRESSURE GAUGES MD26, 36
DIAPHRAGM SEAL WITH FLANGE CONNECTION / FOR PRESSURE GAUGES MD28-38
DIGITAL PRESSURE GAUGE / ELECTRONIC / PROCESS / FOR GAS ME01
RELATIVE PRESSURE TRANSMITTER / VACUUM / THIN-FILM / ANALOG ME11
RELATIVE PRESSURE TRANSMITTER / ABSOLUTE / CERAMIC / THIN-FILM ME12
RELATIVE PRESSURE TRANSMITTER / CERAMIC / THIN-FILM / WITH ANALOG OUTPUT ME49
RELATIVE PRESSURE TRANSMITTER / PIEZORESISTIVE / ANALOG / PROCESS ME50
LIQUID LEVEL TRANSMITTER / ANALOG / EXPLOSION-PROOF / FOR STORAGE TANKS ME56T
RELATIVE PRESSURE TRANSMITTER / CERAMIC / THIN-FILM / WITH ANALOG OUTPUT ME67
RELATIVE PRESSURE TRANSMITTER / MEMBRANE / ANALOG / PROCESS ME69
ABSOLUTE PRESSURE TRANSMITTER / SILICON / ANALOG / HART ME71
LIQUIDS AND GASE PRESSURE AND VACUUM SWITCH / FOR WATER MS10
LIQUIDS AND GASE PRESSURE AND VACUUM SWITCH / FOR WATER / DIAPHRAGM / EXPLOSION-PROOF MS11
MECHANICAL PRESSURE SWITCH / COMPACT / EXPLOSION-PROOF / WITH DIGITAL DISPLAY MS12

Pressure 1Pressure 2 Pressure 3 Pressure 4 Pressure 5

FISCHER DIFFERENTIAL PRESSURE Gauge, Transmitter/Flow and Switch:

Product Description  Model no
ANALOG PRESSURE GAUGE / DIFFERENTIAL PRESSURE / PROCESS / FOR GAS DA01
DIAL PRESSURE GAUGE / DIFFERENTIAL PRESSURE / PROCESS / FOR GAS DA03
DIAL PRESSURE GAUGE / DIFFERENTIAL PRESSURE / PROCESS / FOR GAS DA08
ANALOG PRESSURE GAUGE / DIFFERENTIAL PRESSURE / PROCESS / FOR GAS DA09
ANALOG PRESSURE GAUGE / DIFFERENTIAL PRESSURE / PROCESS / FOR GAS DA10
ANALOG PRESSURE GAUGE / DIFFERENTIAL PRESSURE / FOR GAS / FOR VACUUM DA12
ANALOG PRESSURE GAUGE / DIFFERENTIAL PRESSURE / PROCESS / FOR GAS DA30
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH DIGITAL OUTPUT / RUGGED DE03
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH DIGITAL OUTPUT DE13
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / ANALOG / FOR LIQUIDS AND GASES DE15
DIFFERENTIAL PRESSURE TRANSMITTER / VACUUM / ANALOG / SANITARY DE16
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / ANALOG DE23
DIFFERENTIAL PRESSURE TRANSMITTER / PIEZORESISTIVE / WITH DIGITAL OUTPUT DE25
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / ANALOG / FOR LIQUIDS AND GASES DE28
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH DIGITAL OUTPUT / FOR LIQUIDS AND GASES DE38
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH DIGITAL OUTPUT / FOR LIQUIDS AND GASES DE38_LCD
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH DIGITAL OUTPUT / FOR LIQUIDS AND GASES DE39
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH DIGITAL OUTPUT / FOR LIQUIDS AND GASES
DE39_LCD
 
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH ANALOG OUTPUT / FOR LIQUIDS AND GASES DE40
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH ANALOG OUTPUT / WITH DIGITAL OUTPUT DE44
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH ANALOG OUTPUT / WITH DIGITAL OUTPUT DE44_LCD
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / ANALOG / WITH DIGITAL OUTPUT DE45
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / ANALOG / WITH DIGITAL OUTPUT DE45_LCD
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / ANALOG / WITH DIGITAL OUTPUT DE46
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / ANALOG / WITH DIGITAL OUTPUT DE46_LCD
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / ANALOG / WITH DIGITAL OUTPUT DE49_0_LCD
DIFFERENTIAL PRESSURE TRANSMITTER / ANALOG / WITH DIGITAL OUTPUT / FOR LIQUIDS AND GASES DE49_A_LCD
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH ANALOG OUTPUT / FOR LIQUIDS AND GASES DE50
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / WITH DIGITAL OUTPUT / FOR LIQUIDS AND GASES DE58
DIFFERENTIAL PRESSURE TRANSMITTER / MEMBRANE / ANALOG / STAINLESS STEEL DE70
LIQUIDS AND GASE PRESSURE AND VACUUM SWITCH / DIFFERENTIAL / RUGGED DS11
GAS PRESSURE AND VACUUM SWITCH / DIFFERENTIAL / RUGGED DS13
DIFFERENTIAL PRESSURE SWITCH / INCREASED SAFETY DS21
GAS PRESSURE SWITCH / FOR LIQUIDS / DIFFERENTIAL DS31
GAS PRESSURE SWITCH / DIFFERENTIAL DS35
DIFFERENTIAL PRESSURE FLOW TRANSMITTER / GAS / FOR LIQUIDS FD38_LCD
GAS FLOW TRANSMITTER / FOR LIQUIDS FD39

dasdsdfsdfsdfsfCapture 2Capture 4 35Capture 6asddsaCapture 8

fischer HUMIDITY / TEMPERATURE tRANSMITTER, PROBE AND aNALOG TYPE:

Product Description  Model no
RELATIVE HUMIDITY TRANSMITTER / DUCT-MOUNT / WITH TEMPERATURE MEASUREMENT / WITH DIGITAL OUTPUT FT61
GAS THERMOMETER / ANALOG / INSERTION / DIAL TA
INFRARED THERMOMETER / DIGITAL / INSERTION / INDUSTRIAL TE01
PROBE HEAD-MOUNTED TEMPERATURE TRANSMITTER / RTD / PT100 / DIGITAL TE41
PROBE HEAD-MOUNTED TEMPERATURE TRANSMITTER / RTD / DIGITAL / PROCESS TE42
LIQUID THERMOMETER / GAS EXPANSION WITH CAPILLARY / ANALOG / FLANGE TK
TEMPERATURE SWITCH TS61
THERMOCOUPLE / FLANGE / SCREW-IN / FOR LIQUIDS TT30
THERMOCOUPLE / SCREW-IN / FOR LIQUIDS / FOR GAS TT31
THERMOCOUPLE / SCREW-IN / FOR LIQUIDS / FOR GAS TT32
THERMOCOUPLE / SCREW-IN / FOR LIQUIDS / FOR GAS TT35
THERMOCOUPLE / SCREW-IN / FOR LIQUIDS / FOR GAS TT36
RESISTANCE THERMOMETER / LIQUID / GAS / WITHOUT DISPLAY TW27
RESISTANCE THERMOMETER / LIQUID / GAS / WITHOUT DISPLAY TW31
RESISTANCE THERMOMETER / LIQUID / GAS / WITHOUT DISPLAY TW36
RESISTANCE THERMOMETER / LIQUID / GAS / WITHOUT DISPLAY TW40
RESISTANCE THERMOMETER / LIQUID / WITHOUT DISPLAY / SURFACE-MOUNT TW45
RESISTANCE THERMOMETER / LIQUID / GAS / WITHOUT DISPLAY TW50
RESISTANCE THERMOMETER / LIQUID / GAS / WITHOUT DISPLAY TW68
RESISTANCE THERMOMETER / GAS / WITHOUT DISPLAY / INDUSTRIAL TW70, TW73
RESISTANCE THERMOMETER / LIQUID / WITHOUT DISPLAY / SURFACE-MOUNT TW85
CABLE RESISTANCE THERMOMETER / GAS / WITHOUT DISPLAY / SURFACE-MOUNT TW89

cAP 1Capture 2Capture 3Capture 4Capture 5

fischer SIGNAL CONDITIONING:

Product Description  Model no
POSITION INDICATOR / DIGITAL / PANEL-MOUNT EA10
DIGITAL PRESSURE INDICATOR / DIFFERENTIAL / PROCESS EA14D
LIQUID LEVEL INDICATOR / ELECTRONIC / DIGITAL / FOR TANKS EA14F
DIGITAL PRESSURE INDICATOR / PROCESS EA14M
IN RAIL MOUNT TEMPERATURE TRANSMITTER / 2-WIRE / DIGITAL / 4-20 MA EU41

Cap 1

FISCHER LEVEL MEASURMENTATION FOR LIQUID:

Product Description  Model no
lED DISPLAY / ELECTRONIC / FOR TANK LEVEL MEASUREMENT DISPLAY / ELECTRONIC / FOR TANK LEVEL MEASUREMENT EA01 SERIES
LIQUID LEVEL INDICATOR / DIGITAL / FOR TANKS DE and DS series 
CAPACITIVE LEVEL SENSOR / FOR LIQUIDS / ANALOG / 4-20 MA NC56
CAPACITIVE LEVEL SENSOR / FOR LIQUIDS / ANALOG / FOR STORAGE TANKS NC57
CONDUCTIVE LEVEL SWITCH / FOR LIQUIDS / MULTI-POINT / THREADED NK06
MAGNETIC FLOAT LEVEL SWITCH / FOR LIQUIDS / STAINLESS STEEL / HORIZONTAL NK10
CONDUCTIVE LEVEL SWITCH / FOR LIQUIDS / MULTI-POINT / THREADED NK21
MAGNETIC FLOAT LEVEL SENSOR / FOR LIQUIDS / STAINLESS STEEL / ANALOG NR56
ELECTRONIC LEVEL SWITCH / FOR LIQUIDS / THREADED NS01

Cap 1 Capture 2

For More details please feel free to contact us or mail us at info@alviautomation.com

Level controllers for rainwater utilisation systems

ALVI Automation (India) Pvt Ltd in association with ALVI Technologies brings to you the state of the art German Technology based Level controllers for rainwater utilization systems by JOLA GmbH.

rain water

Level controllers for rainwater utilization systems, FNR range

Operating principle
The components of the FNR range are an FNR fresh water refill controller and one or more suspension electrodes. The FNR 5 and FNR 7 fresh water refill controllers operate according to the conductive measuring principle.
In combination with an LWZ suspension electrode, the FNR 5 is used for purposes such as the controlled refilling of fresh water into a rainwater tank. If the level in the rainwater tank falls below the minimum fill level, a relay output activates refilling of fresh water (e.g. via a solenoid valve). Once the minimum fill level has been reached again, the switching status of the relay output is maintained for the duration of the delay time of approx. 10 seconds (standard) and the refill function is then switched off again. This time delay serves to suppress multiple switching actions in the event of wave motion and results in a level hysteresis whose magnitude depends on the tank dimensions and the strength of liquid inflow.
If, during the refilling cycle, the minimum fill level is not reached again within the monitoring time of approx. 30 seconds (standard), the relay output for refilling is switched off, and a second relay output is activated to issue an alarm due to timeout. This feature is designed to prevent uncontrolled refilling in the event of tank rupture or inflow defects, as well as in the case of electrode cable break, if ther is ice on the electrode or if the electrode has been removed. The various switching statuses are indicated by LEDs. In addition to the features described above, the version FNR 7 is also equipped with 4 LEDs to indicate the tank fill level, and these LEDs are individually controlled via 4 EH or EHK suspension electrode.

clean JOLA

photo1photo2

For more information please mail us at info@alviautomation.com or contact us 

Click here to download the datasheet