Blog

CO – Carbon Monoxide Sensor for Basement car Parking

When it comes to CO – Carbon Monoxide Sensor for Basement Car Parking MSR Germany/GASAlarm make the GAS-CO-300-D model is the Best techno-commercial option in the International HVAC market.

Now available with a special discounted price for the Indian market with the following details :

SPECIFICATIONS:- 

  • Sensor Model Available in Stock: – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three-wire sensor
  • Response time T90:-  ≤ 30 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in: IP65 (Flameproof and weatherproof )
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 12 Years  )

Continue reading “CO – Carbon Monoxide Sensor for Basement car Parking”

Car Parking CO Gas Monitoring and Fan Control Systems

When it comes to Carbon Monoxide Detection in Car Parking CO Gas Monitoring and fan control Systems, Our  European Standard  MSR CO GAS-CO-300-D Sensor Transmitter has great demands in the global market.

Now available with a special  promotional discounted price for the Indian market with the following details :

Ideal for :
Parking area, garages, chiller rooms, and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.

Key Points:- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smoldering fire and smoke detection.
  • VEFSA system (very early fire and smoke alarm)

SPECIFICATIONS:- 

  • Sensor Model Available in Stock: – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three-wire sensor
  • Response time T90:-  ≤ 30 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in: IP65 (Flameproof and weatherproof )
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 12 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 935m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature:–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal:- Standard: 4-20 mA Linear Output, also available in 2-10VDC
  • Flammability: – UL 94: V2
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval:  CE/ UL Enclosure.

LPG Detector – Liquified Petroleum Gas Leak Detection Systems

GasAlarm Systems India pleased to Introduce Highly Accurate LPG Gas Leakage sensor transmitter/detector/analyzer in association with ALVI Technologies- Australia &  MSR Germany having following features:

  • Measuring range: 0-100% LEL (lower explosive limit), 0-100% Vol (analysis)
  • Available Technology: Pellistor / catalytic bead (flammability monitoring), Infra-red
  • Output: 4-20mA, 0-10V, RS485 Modbus, Lon, BACnet
  • Enclosure: IP44, IP54, IP65, Flameproof, Stainless Steel
  • Certificate: UL 61010, UL 2075, ATEX EExd, ATEX EExn, CE
  • Mounting: wall mountable, duct mountable
  • Installation area: safe area, hazardous area, explosion-proof
  • Reverse polarity protected
  • Poisoning protected
  • Low flashing temperature for longer sensor
  • Modular architecture
  • Manual calibration
  • Expected life: 3 years-15 years
  • Low response time

Application areas: Kitchen, gas bank, bottling plant, booster station, gas store, pharmaceutical, cylinder store, gems processing, heat processing, furnace, engine room, testing rooms, automobile, defense, warship, annealing plant, chemical plants, oil & gas, fire safety, domestic gas pipeline, kitchen, refinery, food processing, cement, bearing, machine industry, swimming pool, combustion area, bakery, commercial, hotels, mines, confined space, gasifier, stockyard, oil wells, biogas plant, landfill, boiler plant, thermal power plants, etc

Gas type available: combustible gas detector, confined space gas detector, gas detection system, gas detectors, gas analyzers, exhaust gas analyzers, biogas analyzers, stack gas analyzer, catalytic gas sensor, combustible gas sensor, gas sensors, hydrogen gas sensor, methane detector, LPG bottling plants, LPG burners, LPG cylinder plant, LPG fuel tank, LPG gas leakage sensor, gas train, LPG gas tanker, LPG station, LPG vaporizer, natural gas alarm, natural gas plants, combustion analyzer, biogas generation plant, biogas generator, biogas power generation plant, biomass gasifier, propane vaporizers.

 

For More details please feel free to contact us – Infor@alviautomation.com

“Best Selling” Carbon Monoxide Detector GAS-CO-300-D “on-Sale”

Globally “Best  Selling ” Carbon Monoxide Detector  GAS-CO-300-D  “on-sale ” for the limited period till stocks clear.

German Made GasAlarm model number- GAS-CO-300-D Carbon Monoxide Sensor Transmitter having an excellent high-quality Electrochemical Sensing technology, Top Measurement accuracy, fast response, long service life sensor, two core wiring connection, up to 80% energy-saving, protection class IP65 in the economical discounted price range.

Carbon Monoxide Sensor Transmitter Petrol Diesel Vapour Sensor Transmitter Oxygen Sensor Transmitter

Ideal for :
Basement Car Parking area, garages, chiller rooms, and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.

Key Points:- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smouldering fire and smoke detection
  • VESFA system (very early smoke and fire alarm)

SPECIFICATIONS:- 

  • Sensor Model Available in:  – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two
  • Response time T90:-  ≤ 50 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in IP65
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 11 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 750m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature:–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal:- Standard: 4-20 mA Linear Output
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval: CE, UL

Please watch simple demo of our Gas leak Control and Monitoring System click here

Ethylene (C2H4) Gas Detector for Fruit Ripening Application

We ALVI India and GasAlarm Systems Australia Pleased to introduce our one of best and Economical Sensor Transmitter for the Food Processing Unit.

Globally “Best  Selling ” Economical  MC2-D-S2189-A-0-P-00 Ethylene Sensor Transmitter for Fruit Ripening Chamber and Ethylene Gas Generation Plant    “on-sale ” for the limited period till stocks clear.

Ethylene (C2H4) Gas Sensor Transmitter
Model no: MC2-D-S2189-A-0-P-00
Make: MSR Germany GmbH

With Features :
• Range: 20-2000 ppm C2H4
• Sensor Cell: Semiconductor
• Power Supply: 24 VDC
• Analog Output:4-20mA/2-10 VDC
• Housed in IP65 Polycarbonate enclosure
• Response time: T90 ≤ 10 s
• Life ≥ 5 years
• Wall mounting installation
• Calibration Interval: 1 year
• Continuous monitoring
• Low Zero point drift
• Poisoning stable
• Long-life sensor
• Short circuit and overload protected
• Reverse polarity protected
• Easy maintenance and calibration

* For More details please refer datasheet

Mixed Gas Sensor – Latest Trend in IAQ Monitoring

CO2 IAQ DCV Application_page-0001

CO2 IAQ DCV Application_page-0002

  • CO2 for Demand Control Ventilation (DCV): You can save 40 – 80 % energy cost by installation Indoor Air Quality CO2/VOC Sensors and controlling the Fresh Air Damper. The idea is to maintain the CO2 concentration at 1000 ppm all the time. This application mainly finds use in buildings, offices, conference rooms, cinema halls, hotels, etc. For such application, you are looking for CO2 Sensors n the range of 0 – 2000 ppm with analog output 0 – 10 V or 2-10 V which can be directly connected to the Ventilation Actuator

 

  • CO2 for OH&S Application: Here you need CO2 Sensor with higher concentration to say 0 – 4 % Vol  (40,000 ppm) or 0 – 5 % Vol (50,000 ppm). They find applications in Gas Storage Areas, CO2 fire suppressant systems, mining, CO2 capture and storage, beverage industries, Cellars/Pubs, Wineries, Gas production and storage areas including laboratories where they store large quantities of CO2, etc. Here as per the Work Cover Exposure Standards, the system needs to generate Alarms at 5000 ppm (STEL) and at 30,000 ppm (TWA)for the safety of human beings. For Pubs / Cellars they have now AS 5034 with mandatory requirement to monitor for CO2 and oxygen in their Cellars

 

  • CO2 in Refrigeration Application: Recently due to Green House and Ozone depletion Regulation SUPERMARKETS like Coles, Woolworths, etc have started using CO2 based Natural Refrigerants (going away from using synthetic refrigerants like R134a, R 410 a, R 404 a), etc. We have supplied a number of CO2 Sensors to Coles, Woolworths, etc

 

We have product range meets all the above applications for CO2 gas sensor transmitter.

 

P 1 P 2

polygard-produkte

For more information please email us at info@alviautomation.com or contact us 

“Best Selling” Carbon Monoxide Detector GAS-CO-300-D “on-Sale”

Globally “Best  Selling ” Carbon Monoxide Detector  GAS-CO-300-D  “on-sale ” for the limited period till stocks clear.

German Made GasAlarm model number- GAS-CO-300-D Carbon Monoxide Sensor Transmitter having an excellent high-quality Electrochemical Sensing technology, Top Measurement accuracy, fast response, long service life sensor, two core wiring connection, up to 80% energy-saving, protection class IP65 in economical discounted price range.

Carbon Monoxide Sensor Transmitter Petrol Diesel Vapour Sensor Transmitter Oxygen Sensor Transmitter

Ideal for :
Basement Car Parking area, garages, chiller rooms, and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.

Key Points:- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smouldering fire and smoke detection.
  • VESFA system (very early smoke and fire alarm)

SPECIFICATIONS:- 

  • Sensor Model Available in:  – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two
  • Response time T90:-  ≤ 50 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in IP65
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 11 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 750m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature:–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal:- Standard: 4-20 mA Linear Output
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval: CE, UL

Please watch simple demo of our Gas leak Control and Monitoring System click here

Your safety from unwanted gas leakage is our responsibility

A few days ago there is a massive fire incident occurred in AIIMS Delhi, ONGC- Mumbai, Punjab firecracker factory, many of Hotels in Mumbai, Kamla mills Mumbai, Mumbai, and Delhi have been witness many of the worst fire accidents in past 2 years continuously one by one, all these panic incident took place just because of absence of  Early Gas Leakage Detector and Control Alarm Systems, Every industries Sector get NOC from Government Building Authority by showing Fire Alarm Systems but these fire systems are not reliable in controlling the fire take place due to the combustible or Hydrocarbon gas leakage, therefore, essential for every industry to be equipped with high-quality gas leak detection and control systems and for this we are saying Your safety from unwanted gas leakage is our responsibility.

Hydrocarbon  Combustible gases, short circuit are the main reason for Fire in Automobile Industries, refineries, Hospitals, Hotel, crackers factories, UPS Battery Rooms, Gas Bank, Kitchen, etc. These sectors require high-quality globally trusted Gas Leak Detection Sensor Transmitter with Control Alarm Systems.

We have Best German range of products which are capable to control the panic fire in its initial phase, before it begins, or gets worst due to leakage of flammable gases like Hydrocarbon, LPG, CNG, PNG, Hydrogen, Methane, pentane, propane, etc which meets global standard with high accuracy, fast response and long life in economical price range .

Our Flammable Gas Detector has the following Features : 

Technical Specifications:

  • Measuring Parameters: Hydrocarbon, LPG, PNG, CNG, Hydrogen, Pentane, Propane
  • Sensor Technology: Catalytic bead based pellistor sensor cell
  • Measuring range: 0 ~ 100 % LEL
  • Response time (t90): < 10 sec
  • Control unit: 12-bit microprocessor-based
  • Warm-up time: < 5 mins
  • Auto zero point tracking for drift compensation
  • Power supply: 24 VDC
  • Ingress protection:   IP 65, IP 66, IP 68
  • Enclosure: Poly-carbonate material, also available in Stainless steel (for sensor cell), Cast Aluminium (for transmitter).
  • Output: linear, proportional 4-20mA or 2-10Vdc
  • Mounting: wall, duct, pipeline
  • Safety integrity level: SIL 2
  • Optional: LCD Display, alarm LEDs, potential-free relay contacts, Display Control Monitoring PLC HMI/PID Control Alarm Panel.
  • Also Available for Hazardous area: Zone 1, Zone 2, Atex, IEC-EX, CE approved.

Panel2.

polyxeta-2-Copy-1

 

 

 

 

 

 

For any Techno commercial details please contact us on –  Info@alviautomation.com

Please watch a simple demo of our Gas leak Control and Monitoring System – click here

 

Online Gas Monitoring System For Hospital And Hotel Application

ALVI Automation (India) Pvt Ltd in association with ALVI Technologies Pty Ltd  presents to you Online Gas Monitoring System For Hospital  And Hotel Application: 

  1. For LPG/PNG/CNG/LNG pipeline system, Gas cylinder storeroom, and kitchen application: 
    1. Aim: To identify potential gas leaks from pipeline or gas cylinder
    2. Solution: By installing LPG/PNG/CNG gas sensor transmitter along with control and monitoring system and using set points as per global standards to generate an audio-visual alarm and BMS connectivity             
  2. For control of VFD drive via starter panel of AHU or exhaust fan which Aspirates the air from the kitchen chimney
    1. Aim: To avoid unnecessary usage of electricity and power and operate the air ventilation system only when a high density of smoke is created which are exhausted by varying the speed of the fan
    2. Solution: By installing CO, VEFSA (Very early fire and smoke alarm) gas sensor transmitter along with control and monitoring system and using set points as per global standards (TWA and STEL limits )                 
  3. For Battery/UPS/Server room
    1. Aim: To avoid any leak of hydrogen gas from the batteries that might create an explosive atmosphere when it reached 4% of its vol in air
    2. Solution: By installing MSR H2 gas sensor transmitter along with control and monitoring system and using set points as per global standards (TWA and STEL limits )             
  4. For car park ventilation and basement application:
    1. Aim: To avoid the unnecessary running of exhaust fan, Jet air fan and fresh air fan 24*7 and for human safety and asset protection
    2. Solution:  By installing CO gas sensor transmitter along with control and monitoring system with integration facility with a fire alarm system and using set points as per global standards (TWA and STEL limits )
  5. For STP (Sewage Treatment Plant)
    1. Hydrogen Sulfide and Ammonia are two main parameters restricted by regulations hence continuous monitoring in very essential as the concentration of H2S found in the exhaust air of Sewage Treatment Plant is in the range of 5 – 15 ppm and the emission level for ammonia is typical in the range of 50 to 150 ppm which needs to controlled and detected for human safety
    2. Odor vapor control using VOC(volatile organic component) sensor transmitter
    3. Gas rick area like CH4(Highly explosive), O2 (depletion due to organic CO2) control and monitoring
  6. For online monitoring and control of Indoor Air Quality (IAQ).
    1. Aim: To control and monitoring the indoor air quality inside office premises, Malls, Meeting rooms, theaters, etc.
    2. Solution: by installing CO2, O2, PM2.5, VOC (volatile organic component) gas sensor for continuous monitoring and automatic controlling of centralized AHU to pump in more fresh air whenever necessary to avoid increase of breathing rate drowsiness, pulse rate, headache, dizziness and also helps in energy conservation by avoiding the AHU run in full speed 24×7     
  7. For monitoring and control of Differential air pressure
    1. Aim: As per WHO (World Health Organisation) Building, hospital industries need to maintain positive pressure between the process area and outside surroundings. This positive pressure needs to be maintained to ensure no toxins or dust enters the operation or processing or habitable areas to prevent cross contaminants, Damper control and choking of air filters
    2. Solution: by installing Differential pressure transmitter in Ducts along with remote monitors for online continuous monitoring and alarm generation  

Sensor

For more information please feel free to contact us: