Formaldehyde CH2O Sensor Transmitter
By ALVIALVI – India in association with ALVI – Australia we are pleased to offer MSR Germany Formaldehyde CH2O Sensor Transmitter in India .
DESCRIPTION
CH2O transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect formaldehyde concentrations. Integrated in the transmitter there is a comfortable calibration routine with selective access release. The ADT-53 possesses a standard analog output (0) 4- 20 mA or (0) 2– 10 V DC, and an RS-485 interface. 2 relays with adjustable switching thresholds are available as an option.
APPLICATION
For the detection of formaldehyde within a wide range of industrial and commercial applications. Due to the standard output signal and the RS-485 interface the CH2O transmitter is compatible to the PolyGard Gas Controller series MGC and DGC by MSR-E as well as to any other electronic control or automation system.
FEATURES
Digital processing of the measurement values incl. temperature compensation
Continuous monitoring
Low zero point drift
Good stability to poisoning
Long-life sensor
Modular plug-in technology
Easy maintenance
Comfortable calibration with selective access release
Reverse polarity protected, overload and short-circuit proof
(0) 4 – 20 mA / (0) 2 – 10V analog signal output, selectable
Serial interface RS-485
IP65 protected
Manual calibration via potentiometer (option)
Manual addressing for RS-485 mode (option)
4 – 20 mA analog input for an external AT transmitter (optional)
Approved according to EN 61010-1; ANSI/UL 61010 1; CAN/CSA-C22.2 No. 61010-1
Relay output (optional)
Integrated buzzer (optional)
LED flashlight (optional)
LCD display (optional)
LED status display (optional)
Heating (optional)
Duct mounting (optional)
Contact us on:
Tel: +91 141 2293968, Mail Us -info@alviautomation.com
www.alviautomaton.com is a registered authorized for India and Asia Zone.
SPECIFICATIONS
General sensor performance
Detected gas
Formaldehyde (CH2O) Sensor element Electrochemical, diffusion
Measuring range
0 – 10 ppm (factory set)
adjustable from 0 – 5 to 0 – 10 ppm Temperature range -10 °C to + 45 °C (14 °F to 113 °F) w/o heating
Pressure range
Atmospheric ± 15 % Humidity range 15 – 90 % RH non-condensing (abrupt change of the relative humidity may cause a short-time sensor signal)
Storage temperature
5 °C to 30 °C (41 °F to 86 °F) Storage time Max. 3 months
Mounting height
0.3 to 0.8 m (1 to 2.5 ft.) Accuracy 0.01 ppm
Repeatability
< 2 % of reading Long-term output drift < 2% signal loss/month
Response time
t90 < 50 sec. Sensor life expectancy > 3 years/normal operating environment
Cross sensitivity1
Reaction (%) Carbon monoxide; CO 10 -18 %
Hydrogen, H2
1 – 3 % Electrical
Power supply
18 – 28 VDC/AC, reverse polarity protected
(for 2- wire mode only VDC) Power consumption (without options) – Analog mode – Bus mode 22 mA, max. (0.6 VA) 12 mA, max. (0.3 VA)
Output signal